Gaggenau AH 592-120 Оригінальні інструкції з експлуатації та монтажу - Сторінка 14

Переглянути онлайн або завантажити pdf Оригінальні інструкції з експлуатації та монтажу для Вентиляційна витяжка Gaggenau AH 592-120. Gaggenau AH 592-120 18 сторінок. Freely suspended insular hood
Також для Gaggenau AH 592-120: Інструкція з експлуатації та монтажу (18 сторінок)

Gaggenau AH 592-120 Оригінальні інструкції з експлуатації та монтажу
Flexible aluminium pipes, corrosion-protected
sheet metal pipes and exhaust air pipes whose
material conforms to fire B1 in accordance with
DIN 4102 can be used. Exhaust air pipes should
have a nominal diameter of 150 mm.
Pay particular attention to ensuring that
– the exhaust air ducts and pipes are kept as short
as possible
– the pipes are not laid at an acute angle, but as
bends and that they are inserted into the shaft at
an inclined upward angle and
– there are no cross-sectional constrictions in the
upward direction (this reduces the volume flow).
2.39 - 3.14 m
ceiling height
700
min. 600 over electric hob
min. 700 over gas hob
Fig. 18
251,5
405
1200
As standard, the blow-out opening of the extractor
hood is in the upward direction.
To pass exhaust air through the outer wall, we re-
commend the use of our telescopic wall box
TM 150-045 (Ø 150).
Note:
to prevent the ingress of water, e.g. condensate or
rain water from an uncovered exhaust air shaft, our
condensate separator RV 060-150 must be installed
in the exhaust air line. The condensate separator
must still be accessible after installation.
The duct units listed below are available depen-
ding on the height of the ceiling:
Stainless steel-design ventilation duct:
LK 590-010 for ceiling heights of 2.39 - 2.64 m
LK 590-020 for ceiling heights of 2.64 - 2.89 m
LK 590-030 for ceiling heights of 2.89 - 3.14 m
Aluminium-design ventilation duct:
LK 590-011 for ceiling heights of 2.39 - 2.64 m
LK 590-021 for ceiling heights of 2.64 - 2.89 m
LK 590-031 for ceiling heights of 2.89 - 3.14 m
The dimensions above refer to a distance of 1.60 m
from the floor to the bottom edge of the hood.
If required, custom made duct units are available at
an extra charge.
The electrical socket must be placed within the
ventilation duct on the ceiling.
13