Aircraft AITHRE SHIELD EX Series Посібник - Сторінка 3

Переглянути онлайн або завантажити pdf Посібник для Аксесуари Aircraft AITHRE SHIELD EX Series. Aircraft AITHRE SHIELD EX Series 8 сторінок. Co and o2 psi sensors for experimental aircraft

If using the AF-EMS for the EX 1.0 or EX 2.0, the calibration settings are different. Go to item '3. Aircraft
Info' and press SEL. After that, set item '7. Cool Temp Usage' to CO DETECTOR like this:
Next go to item '43. CO Detector' and press SEL. You will need to set your configuration to match the
following.
DYNON ADDENDUM
Hook up the red 5V power, black ground, white (CO) analog output wire, and yellow (tank psi – EX 3.0
only) analog output wire using the SV-EMS. The white and yellow analog output wires should go to one
of the following pins of the SV-EMS: 8, 22, 23, 31.
Contact Don Jones at Dynon Support to download the Aithre Shield EX widgets. Make sure to specify to
Don whether you need the CO and/or the tank psi widgets.
GARMIN G3X ADDENDUM
Hook up the red 5V power, black ground, white (CO) analog output wire, and yellow (tank psi – EX 3.0
only) analog output to the GEA 24. Make sure the black ground wire is grounded to aircraft ground. The
following pinout from the G3x manual shows which pins are available for 5V and analog inputs.