Agrilight AGRILED pro 16 Посібник з експлуатації та монтажу - Сторінка 9

Переглянути онлайн або завантажити pdf Посібник з експлуатації та монтажу для Світильник Agrilight AGRILED pro 16. Agrilight AGRILED pro 16 16 сторінок.

If you wish to operate the fixture with a DALI light management system:
Connect the two-core DALI cable of the light management system to the two-core white terminal in the
fixture (13)
Use a 2-core cable with a diameter of 3.5-7 mm for the DALI connection. For further
information, refer to the manual of the AGRIBOX pro.
Several fixtures can be connected to one system (8). Refer to the website for further information on th
electrical installation.

6 Commissioning

Switch on the fixture to test its function. See chapter 8 if the fixture does not switch o

7 Maintenance and Maintenance Plan

Allow the whole electrical installation to cool down for at least 30 minutes before starting
maintenance work.
The fixture can be cleaned using a damp cloth
Clean the glass fixture cap once a month
Remove any dust from the cooling fins. This will prolong the service life of the fixtur
Do not use abrasive cleaning agents.
Do not use caustic cleaning agents or products with bleach.
Consult a cleaning specialist if the fixture is heavily soiled

8 Faults and Repairs

Allow the whole electrical installation to cool down for at least 30 minutes before starting any work.
Do not replace any parts yourself (not even LEDs or LED modules).
If the fixture does not switch on
Check the wiring. If the wiring is damaged, have the wiring replaced by a qualified electrician usin
original wiring from the manufacturer.
Replace the power supply cable:
1. Loosen the four Torx screws of the end cap using a Torx 20 screwdriver.
2. Remove the end cap without the Agrilight logo (9).
3. Disconnect the power supply cable from the four-pin plug.
4. Remove the old power supply cable.
5. Pull a new power supply cable through the gland in the end cap.
6.
Use only a power supply cable with a diameter of 7-13 mm.
7. Connect the power supply cable to the four-pin plug; refer to the table in section 5.3 for the colour coding.
8. Fit the end cap and insert the Torx screws again.
9. Tighten the Torx screws to a torque of 1 Nm. Use a Torx 20 screwdriver.
If the LEDs do not function correctly, you can check whether the wiring of the LED drivers and LEDs is
correctly connected. Proceed as follows:
1. Loosen all the Torx screws of both end caps using a Torx 20 screwdriver.
2. Remove the end cap with the Agrilight logo (10).
3. Remove the (white) eight-pin plug (11).
4.
The product may be damaged if you do not disconnect the eight-pin plug.
5. Remove the end cap without the Agrilight logo (9).
6. Remove the black four-pin power supply plug (12).
7. If installed, remove the white two-pin DALI plug (13).
9