R E M O V A L / I N S TA L L AT I O N O F M O T O R H E A D F R O M M A I N A S S E M B LY
If the filter element becomes clogged or to clean the inner portions of the
canister the Motorhead Assembly must then be removed to perform
cleaning. When removal becomes necessary for cleaning or other service,
follow the procedures described below.
Removal
1. Unplug the unit before attempting service or maintenance work.
2. Remove Top Lid by unlatching (4) hinges.
O P E R AT I N G T I P S A N D T R O U B L E S H O O T I N G
DO NOT USE A BLOW GUN WHEN CLEANING MOTORHEAD ASSEMBLY.
Decrease in Vacuum Performance
1. If the pre-filter (P/N 62003) should become damaged or badly
clogged, replace with a new one. It is recommended to replace the
pre-filter every third time you replace the collection filter.
2. Check all the vacuum lines for blockage or leakage.
T E C H N I C A L S P E C I F I C AT I O N S – I N D U S T R I A L V A C U U M S Y S T E M
Model No. ........................ 61500
Noise Level ...................... 76 Decibels
Air Pressure .................... 90 PSIG (6.2 Bar)
Filter ................................ H.E.P.A. (0.3 micron)
Unit Capacity Size............ Dry: 10 gallon (44 liter)
.......................................... Wet: 12 gallon (45.4 liter)
Static H
O Lift .................. 88" (2.2 m)
2
Air Displacement ............ 130 cfm
3 1 9 6 0 C O N D U C T I V E C O A X I A L V A C U U M H O S E A S S E M B LY
Swivel Cuff
1-1/4" Vac Hose
P/N 31907
P/N 31969
DYNABRADE, INC.
8989 Sheridan Drive • Clarence, New York 14031-1419 • Phone: (716) 631-0100
Fax: 716-631-2073 • US Consumers Call Toll Free: 1-800-828-7333
DYNABRADE INTERNATIONAL
8989 Sheridan Drive • Clarence, New York 14031-1419 • Phone: (716) 631-0100
Fax: 716-631-2524 • Canadian Consumers Call Toll Free: 1-800-344-1488
DYNABRADE EUROPE S.à r. l.
Zone Artisanale • L-5485 Wormeldange-Haut, Luxembourg
Phone: +352 768 494 1 • Fax: +352 768 495
DYNABRADE DO BRASIL
Rua Mário Fongaro • 421 – Vila Marlene • São Bernardo do Campo
SP – CEP 09732-530 • Telefax: (11) 4124-6040
© DYNABRADE, INC., 2010
Buy parts on line at https://Dynashop.co.uk/ for all things Dynabrade
Cuff with Air Line Exit
1-1/4" Vac Hose
P/N 31967
P/N 31970
Air Line Assembly - 11" (28cm) of Air
Line Assembly will Extend Past the Cuff
Dynabrade Coupler
P/N 94960
Dynabrade Male Plug
P/N 95675
PRINTED IN USA
3. Use a conventional vacuum cleaner to clean entire inside of
Motorhead Assembly and canister.
Upon completion of the service work, install top lid according to
the following procedure:
Installation
1. Place cleaned unit onto the canister and latch (4)
hinges to properly attach the lid. Unit is now ready for
operation.
Vacuum Stops During Use
1. This vacuum is protected by both a resettable circuit breaker and an
Electronic Thermal Protection device. If the unit shuts down, check
and reset the circuit breaker. If the unit does not restart the thermal
protection may have shut down as a result of over temperature. Once
it has cooled the unit will restart.
No. of Vacuum Outlets .... 2
No. of Pneumatic Outlets 2 (3/8" NPT)
Construction .................... Stainless Steel Canister
Remainder: Plastic and Metal Components.
Dust & Debris Collection Pre Filter, H.E.P.A.(0.3 micron) Filter
Collection Filter.
Standard Vacuum Hose .. (2) 20' x 1-1/4" Light Weight Coaxial Hose
(Conductive, P/N 31960)
Cord Set............................ 37' (11.3 m)
Cuff with Air Line Exit
1-1/4" Vac Hose
P/N 31967
P/N 31969
36" (91cm) of
Air Line
Assembly
will Extend Past
the Cuff
www.dynabrade.com
Cuff
P/N 31904
Dynabrade Female Plug
P/N 95677
DYNABRADE
PD10.33_09/10
®