ADEMCO Counterforce CFV15PCN Посібник з програмування - Сторінка 5
Переглянути онлайн або завантажити pdf Посібник з програмування для Система безпеки ADEMCO Counterforce CFV15PCN. ADEMCO Counterforce CFV15PCN 16 сторінок.
∗
66
ARM AWAY/STAY RPT CODE
∗
67
RF XMTR LOW BAT REPORT CODE
∗
68
CANCEL REPORT CODE
RESTORE REPORT CODES (
∗
70
ALARM RESTORE RPT CODE
∗
71
TROUBLE RESTORE RPT CODE
∗
72
BYPASS RESTORE RPT CODE
∗
73
AC RESTORE RPT CODE
∗
74
LOW BAT RESTORE RPT CODE
∗
75
RF XMTR LO BAT RST RPT CODE
∗
76
TEST RESTORE RPT CODE
OUTPUT AND SYSTEM SETUP (
∗
77
DAYLIGHT SAVINGS TIME
START\END MONTH
∗
78
DAYLIGHT SAVINGS TIME
START\END WEEKEND
∗
∗
∗
∗
79,
80,
81,
82
MENU MODES
∗
84
AUTO STAY ARM
∗
85
CROSS ZONE TIMER
This option not for use in UL installations.
∗
86
CANCEL VERIFY KEYPAD DISPLAY
∗
87
MISC. FAULT DELAY TIME
(used with Configurable Zone Types "digit 6")
∗
88
PROGRAM MODE LOCKOUT
OPTIONS
∗
89
EVENT LOG FULL REPORT CODE
∗
90
EVENT LOG ENABLES
∗
91
OPTION SELECTION
[0,0] See box on previous page.
Away Stay
|
|
∗
∗
70 –
76)
[1]
|
|
|
|
|
|
∗
∗
77 –
93)
|
|
[1][5]
These are Menu Mode commands, not data fields, for Output Device Mapping,
Output Programming, Zone List Programming, and Alpha Programming
respectively. See page 2 and their respective sections in the Installation and Setup
Guide for procedures.
[1]
[0]
(assign cross zones on
zone list 4, using *81 Menu
mode)
[1]
[0]
|
[3]
NOTE : System messages are
logged when any non-zero
selection is made.
[8]
.
[10]
See box on previous page.
UL: must be enabled if wireless devices are used
[10]
See box on previous page.
See box on previous page.
[10]
See box on previous page.
[00]
See box on previous page.
[10]
See box on previous page.
[10]
See box on previous page.
[10]
See box on previous page.
UL: must be enabled if wireless devices are used
[10]
See box on previous page.
0 = Disabled
[4][10]
1-12 = January-September (1 = Jan, 2 = Feb, etc)
#+10 = October; #+11 = November; #+12 = December
0 = disabled, 1 = first, 2 = second, 3 = third
4 = fourth, 5 = last, 6 = next to last, 7 = third to last
0 = no, 1 = yes, auto-stay arm enabled
0 = 15 seconds
1 = 30 seconds
2 = 45 seconds
3 = 60 seconds
4 = 90 seconds
5 = 2 minutes
0 = no, 1 = yes
0 = 15 seconds
1 = 30 seconds
2 = 45 seconds
3 = 60 seconds
4 = 90 seconds
5 = 2 minutes
UL: may only be used on non-burglar alarm/ non-fire alarm
zones when used in fire and/or UL burglar alarm installation
Enhanced Program Mode Lockout Options:
[0]
0 = standard *98 installer code lockout (reentry only by
[∗] + [#] within 50 seconds after power up)
1 = lockout [∗] + [#] reentry after *98 exit (installer code
only)
2 = not used
3 = lockout all local programming after *98 exit (reentry
via downloader only)
See box on previous page for report code entries.
[00]
0 = None; 1 = Alarm/Alarm Restore
2 = Trouble/Trouble Restore;
4 = Bypass/Bypass Restore;
8 = Open/Close. Example: To select "Alarm/Alarm
Restore", and "Open/Close", enter 9 (1 + 8); To select
all, enter #15.
0 = None
4 = AAV UL: must use ADEMCO UVCM module
8 = Exit Delay Restart/Reset UL: must be disabled
#+12 = AAV and Exit Delay Restart/Reset
SIA Installations: Exit Delay should be enabled.
– 5 –
6 = 2-1/2 min
#+12 = 8 min
7 = 3 min
#+13 = 10 min
8 = 4 min
#+14 = 12 min
9 = 5 min
#+15 = 15 min
#+10 = 6 min
#+11 = 7 min
6 = 2-1/2 min
#+12 = 8 min
7 = 3 min
#+13 = 10 min
8 = 4 min
#+14 = 12 min
9 = 5 min
#+15 = 15 min
#+10 = 6 min
#+11 = 7 min