ARM AWAY/STAY RPT CODE
67
RF XMTR LOW BAT REPORT CODE
68
CANCEL REPORT CODE
RESTORE REPORT CODES (
70
ALARM RESTORE RPT CODE
71
TROUBLE RESTORE RPT CODE
72
BYPASS RESTORE RPT CODE
73
AC RESTORE RPT CODE
74
LOW BAT RESTORE RPT CODE
75
RF XMTR LO BAT RST RPT CODE
76
TEST RESTORE RPT CODE
OUTPUT AND SYSTEM SETUP (
77
DAYLIGHT SAVINGS TIME
START\END MONTH
78
DAYLIGHT SAVINGS TIME
START\END WEEKEND
79,
80,
81,
82
MENU MODES
84
AUTO STAY ARM
85
CROSS ZONE TIMER
This option not for use in UL installations.
86
CANCEL VERIFY KEYPAD DISPLAY
87
MISC. FAULT DELAY TIME
(used with Configurable Zone Types "digit 6")
88
PROGRAM MODE LOCKOUT
OPTIONS
89
EVENT LOG FULL REPORT CODE
90
EVENT LOG ENABLES
91
OPTION SELECTION
[0,0] See box on previous page.
Away Stay
|
|
70 –
76)
[1]
|
|
|
|
|
|
77 –
93)
|
|
[1][5]
These are Menu Mode commands, not data fields, for Output Device Mapping,
Output Programming, Zone List Programming, and Alpha Programming
respectively. See page 2 and their respective sections in the Installation and Setup
Guide for procedures.
[1]
[0]
(assign cross zones on
zone list 4, using *81 Menu
mode)
[1]
[0]
|
[3]
NOTE : System messages are
logged when any non-zero
selection is made.
[8]
.
[10]
See box on previous page.
UL: must be enabled if wireless devices are used
[10]
See box on previous page.
See box on previous page.
[10]
See box on previous page.
[00]
See box on previous page.
[10]
See box on previous page.
[10]
See box on previous page.
[10]
See box on previous page.
UL: must be enabled if wireless devices are used
[10]
See box on previous page.
0 = Disabled
[4][10]
1-12 = January-September (1 = Jan, 2 = Feb, etc)
#+10 = October; #+11 = November; #+12 = December
0 = disabled, 1 = first, 2 = second, 3 = third
4 = fourth, 5 = last, 6 = next to last, 7 = third to last
0 = no, 1 = yes, auto-stay arm enabled
0 = 15 seconds
1 = 30 seconds
2 = 45 seconds
3 = 60 seconds
4 = 90 seconds
5 = 2 minutes
0 = no, 1 = yes
0 = 15 seconds
1 = 30 seconds
2 = 45 seconds
3 = 60 seconds
4 = 90 seconds
5 = 2 minutes
UL: may only be used on non-burglar alarm/ non-fire alarm
zones when used in fire and/or UL burglar alarm installation
Enhanced Program Mode Lockout Options:
[0]
0 = standard *98 installer code lockout (reentry only by
[∗] + [#] within 50 seconds after power up)
1 = lockout [∗] + [#] reentry after *98 exit (installer code
only)
2 = not used
3 = lockout all local programming after *98 exit (reentry
via downloader only)
See box on previous page for report code entries.
[00]
0 = None; 1 = Alarm/Alarm Restore
2 = Trouble/Trouble Restore;
4 = Bypass/Bypass Restore;
8 = Open/Close. Example: To select "Alarm/Alarm
Restore", and "Open/Close", enter 9 (1 + 8); To select
all, enter #15.
0 = None
4 = AAV UL: must use ADEMCO UVCM module
8 = Exit Delay Restart/Reset UL: must be disabled
#+12 = AAV and Exit Delay Restart/Reset
SIA Installations: Exit Delay should be enabled.
– 5 –
6 = 2-1/2 min
#+12 = 8 min
7 = 3 min
#+13 = 10 min
8 = 4 min
#+14 = 12 min
9 = 5 min
#+15 = 15 min
#+10 = 6 min
#+11 = 7 min
6 = 2-1/2 min
#+12 = 8 min
7 = 3 min
#+13 = 10 min
8 = 4 min
#+14 = 12 min
9 = 5 min
#+15 = 15 min
#+10 = 6 min
#+11 = 7 min