TO PROGRAM SYSTEM STATUS & RESTORE
REPORT CODES ( 60– 75):
With a 3+1 or 4+1 Standard Format: Enter a code in the first
box: 1–9, 0, B, C, D, E, or F. Enter #+10 for 0, #+11 for B, #+12
for C, #+13 for D, #+14 for E, #+15 for F.
A 0 (not #+10) in the first box will disable a report.
A 0 (not #+10) in the second box will result in automatic
advance to the next field when programming.
With an Expanded or 4+2 Format: Enter codes in both boxes
(1st and 2nd digits) for 1–9, 0, or B–F, as described above.
A 0 (not #+10) in the second box will eliminate the expanded
message for that report.
A 0 (not #+10) in both boxes will disable the report.
With ADEMCO Contact ID ® Reporting: Enter any digit (other
than 0) in the first box, to enable zone to report (entries in the
second boxes will be ignored).
A 0 (not #+10) in the first box will disable the report.
Examples:
For Code 3 (single digit), enter:
For Code 3 2 (two digits), enter:
For Code B 2 (Hexadecimal), enter:
70 ALARM RESTORE RPT CODE
2nd digit is automatically sent as the 2nd digit of
the zone alarm report code programmed in 56,
if expanded or 4+2 reporting is selected.
71 TROUBLE RESTORE RPT CODE
72 BYPASS RESTORE RPT CODE
80 OUTPUT RELAYS
81 ZONE LISTS FOR
OUTPUT RELAYS
82 CUSTOM ALPHA EDITING
56) See procedure in Installation Instructions.
91 OPTION SELECTION (AAV)
0 = None;
4 = AAV;
8 = Enable Exit Delay Restart;
# + 12 = Both enabled
0 for UL installations.
NOTE: AAV should not be used when Paging or
Alarm reports are being sent to a secondary number.
See Audio Alarm Verification (AAV) in the Installation
Instructions.
† Entry of a number other than one specified will give unpredictable results.
SYSTEM STATUS REPORT CODES ( 60 – 68)
3 | 0
3 | 2
#+11 | 2
RESTORE REPORT CODES ( 70 – 75)
[0]
|
[00]
|
[00]
OUTPUT AND SYSTEM SETUP ( 80 – 93)
Program only if relays are
to be used. Refer to the
Output Relays Worksheet
on page 8.
Also entered from field
(
[0]
60 TROUBLE REPORT CODE
61 BYPASS REPORT CODE
62 AC LOSS REPORT CODE
63 LOW BAT REPORT CODE
64 TEST REPORT CODE
65 OPEN/EXIT ALARM RPT CODE
2nd digit of OPEN REPORT is automatically sent as the
user number if expanded or 4+2 reporting is selected.
2nd digit of EXIT ALARM REPORT is automatically sent as
the 2nd digit of the zone alarm report code programmed in
56, if expanded or 4+2 reporting is selected.
66 AWAY/STAY CLOSE RPT CODE
2nd digit of any CLOSE REPORT is automatically sent as
the user number, if expanded or 4+2 reporting is selected.
67 RF XMTR LOW BAT RPT CODE
68 CANCEL REPORT CODE
73 AC RESTORE RPT CODE
74 LOW BAT RESTORE RPT CODE
75 RF XMTR LO BAT RST RPT CODE
92 REPORTS PER ARMED PERIOD
0 = 10 max total alarm + alarm restore;
1 = unlimited
93 DYNAMIC SIGNALING
DS Delay; 0-15 times a 15-sec delay
1 = 15 secs; 2 = 30 secs; 3 = 45 secs;
4 = 60 secs...etc.
0 = No delay. (Reports are sent to both
UL installations: set for 0 (No delay)
DS Priority; 0 = Send message to Primary
1 = Send message to LRR first