INSTALLATION
• Turn the alarm body anticlockwise and remove the
mounting bracket.
• Position the bracket into the desired position, mark
installation holes of the bracket with pencil.
• Bore two 5mm installation holes with an electric drill. Insert
the two plastic plugs into the holes with a hammer.
• Attach the bracket to the plastic plugs by driving the
screws into the plastic plugs (See Diagram 7).
• Fit the alarm on the bracket and turn the alarm body
clockwise, until you feel a click.
• Press and hold the button to test the unit. The alarm will
sound once indicating a successful test. If there is no
sound, it may indicate a defective alarm or flat battery, you
can refer to "Troubleshooting" for solution or return to your
retailer during warranty period.
• When testing an interconnected smoke alarm all paired
alarms should also sound for 1 minute. This will also test if all
smoke alarms are successfully wirelessly interconnected. If
an alarm does not sound, re-pair it with the primary alarm.
• If you have any questions on installation, please contact
your retailer.
• If you have any questions on installation, you can contact
your retailer.
WARNING: TO PREVENT THE RISK OF INJURY, THIS
UNIT MUST BE SECURELY FASTENED TO THE WALL OR
CEILING IN ACCORDANCE WITH THESE INSTALLATION
INSTRUCTIONS.
TROUBLESHOOTING
PROBLEM
Alarm does not sound during testing
The alarm "chirps" and red LED flashes
every 40 seconds
The alarm "chirps" every 40 seconds.
(no led Flash)
Smoke Alarm sounds unnecessarily. (e.g.
for no apparent reason, while cooking,
when someone is showering etc.)
Interconnected smoke alarm does not
sound when others do.
EMERALD PLANET HEAD OFFICE - SYDNEY Unit 2 / 29 Mitchell Road, Brookvale NSW 2100 Australia P 02 9466 6000
DIAGRAM 7
TROUBLE SHOOTING
1.
Fit the alarm on the bracket and turn the alarm body clockwise
for POWER ON.
2.
Clean smoke alarm. Refer to "Maintenance & Cleaning" section.
3.
Contact supplier for advice
1.
The battery is low. Replace the battery.
Refer to "Battery Replacement" section above
1.
Clean smoke alarm. Refer to "Maintenance & Cleaning" section.
2.
Replace smoke alarm if problem persists.
1.
Press the "Test" button to pause the alarm.
2.
Clean smoke alarm. Refer to "Maintenance & Cleaning" section.
3.
Move smoke alarm to new location if necessary and press the "Test" button.
1.
Re-pair smoke alarm with primary alarm.
2.
Move smoke alarm closer to nearest smoke alarm.