Automated Logic BACview2 Посібник з експлуатації обладнання - Сторінка 4

Переглянути онлайн або завантажити pdf Посібник з експлуатації обладнання для Клавіатура Automated Logic BACview2. Automated Logic BACview2 5 сторінок.

I/O
E xp a n s io n
N e t
+
C M n e t
N e t
-
O p t i o n a l
S h i e l d
T yp e: 0 32 0
MODULE
C a t. #
Control Module
L IST E D
8 8 FO
A
IN 9
A
B
IN1
B
A
IN 10
A
B
IN2
B
A
IN 11
A
B
IN3
B
A
IN 12
A
B
IN4
B
A
IN 13
A
B
IN5
B
A
IN 14
A
B
IN6
B
A
A
IN 15
B
B
IN7
A
A
B
IN 16
B
IN8
U n i v e r s a l I n p u t
1 - 1 6
M o d e S e l e c t
0 - 2 0 m A
0 - 5 V d c
T h e r m i s t o r
I/O
/
E xp a n s io n
d r y c o n ta c t
Figure 3. Type I Mounting
3. Use the rear mounting plate as a template
to drill four mounting holes onto a panel
directly above the module the BACview
will communicate with.
4. Feed the ribbon cable through the ribbon
hole on the rear mounting plate.
5. Pull the ribbon cable to the side and
mount the rear mounting plate onto the
panel using the four mounting holes
shown in Figure 2 on page 3. Be sure not
to bend or pinch the ribbon cable beneath
the rear mounting plate.
6. Connect the ribbon cable to the face of the
2
BACview
.
7. Reattach the BACview
mounting plate.
8. Connect the ribbon cable to the module's
Auxiliary Device port (see Figure 3).
1. Turn off the power to the module the
Revised 11/19/99 • BACview
R x
T x
R un
Er ro r
P o w er
O n
O f f
G n d
2 4 V a c
C l a s s 2
U s e S i n g l e C l a s s 2
2 4 V a c , 5 0 - 6 0 H z
3 5 V A , 1 . 5 A
S o u r c e O n l y
U s e C o p p e r
C o n d u c t o r s O n l y
C M n e t M od e
A rc 15 6
960 0/ 38.4 k
A uxil ary
D e vic e
P o rt
LI S TE D
O p e n En erg y
Ma na ge m ent Equ i pmen t
C
R
R
8 8F O
A c c es s
P or t
B
A - I n p u t S i g n a l
IN 24
A
B - G n d / L o o p P o w e r
B
IN 3 2
B
A
IN 23
A
B
B
IN 3 1
A
IN 22
A
B
IN 3 0
B
A
IN 21
A
B
B
A
IN 2 9
A
IN 20
B
B
A
IN 2 8
IN 19
A
B
B
A
IN 2 7
A
IN 18
B
B
A
IN 2 6
A
IN 17
B
A
IN 2 5
U n i v e r s a l In p u t
1 7 - 3 2
M o d e S e l e c t
M od ule
A ddr es s
0 - 2 0 m A
0 -5 V d c
T h e r m i s t o r
/
d r y c o n t a c t
2
to the rear
2
Hardware Guide
Type II Mounting
2
The BACview
a panel box. With this type of mounting the
ribbon cable is fed through the door and
connected to the module (see Figure 4 on
page 5).
1. Remove the rear mounting plate screws
(see Figure 2 on page 3 for location) from
the BACview
2. Remove the rear mounting plate from the
2
BACview
.
3. Use the rear mounting plate as a template
to drill four mounting holes through the
door of a panel box.
4. Use the rear mounting plate as a template
to cut a hole for the ribbon cable through
the door of a panel box.
5. Feed the ribbon cable through the ribbon
hole on the rear mounting plate and the
panel door.
6. Mount the rear mounting plate onto the
panel using the four mounting holes
2
shown in Figure 2 on page 3. Be sure not
to bend or pinch the ribbon cable beneath
the rear mounting plate.
7. Connect the ribbon cable to the face of the
2
BACview
.
8. Reattach the BACview
mounting plate.
9. Connect the ribbon cable to the module's
Auxiliary Device port mounted inside the
panel box (see Figure 4 on page 5).
2
BACview
CAUTION The BACview
(less than 30 VAC, 100VA max). Take
appropriate isolation measures when
mounting a BACview
where Class 1 devices or wiring are present.
2
BACview
will communicate with.
4
© 1999 Automated Logic Corporation
can be mounted on the door of
2
.
2
to the rear
Wiring
2
is a Class 2 device
2
in a control panel