HIBLOW HP-10 Посібник - Сторінка 4
Переглянути онлайн або завантажити pdf Посібник для Повітряний компресор HIBLOW HP-10. HIBLOW HP-10 5 сторінок.
HP- 10〜50
CAUTION
!
●Be sure to unplug the pump unit.
●When performing replacement work, the pump body may be still hot and you may get
burnt. Therefore, wait until the pump has been allowed to cool.
●Be sure to remove the chamber block and the actuating rod before replacing the
electromagnet.
●It is better to let an experienced technician handle the soldering process.
Take precautions against being burnt.
●In case of HP-10/20, do the same way of replacing the electromagnet.
STEP
STEP
REMOVING THE ELECTROMAGNET
1
1
Cut the wire from the terminals on the
electromagnet with nippers.
●It is recommended that you make a note of the wiring.
STEP
STEP
2
2
Remove the nuts with the box driver.
(7mm wrench.)
STEP
STEP
3
3
Pull out electromagnets from the pump body.
4
REPLACING THE ELECTROMAGNET