Automatic Solutions FBK Посібник з встановлення та експлуатації - Сторінка 9

Переглянути онлайн або завантажити pdf Посібник з встановлення та експлуатації для Домофонна система Automatic Solutions FBK. Automatic Solutions FBK 17 сторінок. Gsm intercom system

The table below show the complete list of features in the cellular part of the intercom.
TIP: Programming messages below must begin with *12*1234# (if 1234=default passcode)..
Parameter
Description
01????#
Change programming password
Change access control password (SMS control of relays, or non-stored
02????#
numbers can call intercom & enter code to activate output 1).
Change monitoring mode password (user can call the intercom, enter this
03????#
pass code to listen in and speak)
1n????#
Store dialling out numbers. (n = 1, 2 or 3 position)
1n*#
Delete a dial out number. (n = 1, 2 or 3)
3?#
Speaker volume. Where ? = 1-3. 1 = lowest, 3 = highest.
4?#
Microphone volume. Where ? = 1-3. 1 = lowest, 3 = highest.
51?#
Relay time. ? = seconds, 1-9999.
52??#
Calling time - adjust this to avoid voicemail picking up a call (10-99 secs)
53????#
Talking time. 005-999 seconds. Must be 3 digits.
Max monitoring time (for listen in mode when calling the intercom) 00-60
55??#
mins. 00 = no limit.
Store a service number to receive a scheduled call or SMS from the unit
77number#
and prevent inactive SIM being turned off by provider.
Set the time schedule for the intercom to make a scheduled call or SMS
57??#
to the service number. 00-60 day time schedule. 00 = no call or SMS.
58?#
Choose between scheduled call or scheduled SMS. 1 = SMS. 2 = call.
77*#
Delete the stored service number
71???#
Stores country code.
72number#
Store caller ID number. Max 14 digits. Only last 6 digits compared.
73number#
Delete caller ID number. (number = phone number to be deleted).
73*#
Delete all caller ID numbers
Service & diagnostic messages (no passcode required for these!)
*20#
Check reception level 1-31 (no passcode needed)
*21#
Check stored numbers. O = dial out number. I = dial in number. E = end
*22#
Check input status and relay status. (No passcode needed)
999#
Send with passcode string to clear all programming.
P a g e
| 9
GSM unit complete list of parameters
Changing pass codes
Dial out numbers
Volume controls
Scheduled service calls
Caller ID features
Restore Defaults
Timings
Default
1234
5678
1212
N/A
N/A
3
3
1 sec
20 secs
60 secs
10 mins
N/A
00
1
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A