Automatic Technology GDO-8 Shed Master Посібник користувача - Сторінка 9

Переглянути онлайн або завантажити pdf Посібник користувача для Відкривач гаражних дверей Automatic Technology GDO-8 Shed Master. Automatic Technology GDO-8 Shed Master 20 сторінок. Weather resistant roll up door opener
Також для Automatic Technology GDO-8 Shed Master: Інструкція з монтажу (2 сторінок)

Automatic Technology GDO-8 Shed Master Посібник користувача

7. Safety Testing

7.1 Test the Close Cycle

a. Press the transmitter to open the door.
b. Place a piece of timber approximately 40mm high on
the floor directly under the door
c. Press the programmed transmitter to close door.
d. The door should strike the object and re-open.

7.2 Testing the Open Cycle

a. Press the transmitter to close the door
b. Press again to open the door.
c. When the door reaches approximately half way,
firmly grab the door's bottom rail - the door should
stop.
If the door does not reverse readily when closing, or
stop when opening, put the door into manual and
contact your installer immediately for a door service.
If transmitter is not programmed,
Refer to Section 8 to program
transmitter.
Fig. 7.1

7.3 Test the Manual Door Operation

Periodically disengage the opener (Section 6.1)
and manually operate the door. The door must be
smooth to operate by hand. The force required on
the bottom rail should not exceed 15 kg.
GDO-8 ShedMaster
(Fig 7.1)
(Fig
7.2).
(Fig.
7.1).
Select the button on
the transmitter that has
been programmed to
operate the door.
®
Home Owner's Manual
CAUTION: Take care when
completing a safety test. Failure
to follow this warning can result
in serious personal injury and/or
property damage.
WARNING! If the door is closing
and is unable to re-open when
obstructed, discontinue use.
Do not use a door with faulty
obstruction sensing. Contact your
door professional for support.
40mm
Fig. 7.2
WARNING!
manual release mechanism to
ensure that the manual release
is easy to operate. No more than
15 kg of force should be required
to disengage the door using the
manual release cord. If excessive
force is required contact your
door professional immediately
and ask them to reset the close
limit position.
9
Please
test
the