antee period, DYNACO will replace any non-stand-
ard parts at net prices. Many of the components are
standard items which can be purchased from most
electronic supply stores.
If transformers are returned for factory repair or
replacement, they should be removed from the equip-
ment without cutting leads short. If leads are cut
rather than unsoldered so that they are unusable, the
transformer guarantee is void.
In the event the assembled kit does not function
properly or breaks down after use, DYNACO will
service the kit for a fee of $5.00 plus the cost of parts
which have been damaged or are past guarantee. This
service facility is not available for kits which are in-
completely wired or which have been wired with other
than rosin core solder, or in which changes have been
made without factory authorization. In addition, NO
PARTS WILL BE REPLACED NOR WILL ANY
SERVICE BE RENDERED FOR KITS WHERE
THE GUARANTEE POST CARD HAS NOT
BEEN RETURNED. THE SERIAL NUMBER
ON THIS INSTRUCTION BOOK MUST BE
MENTIONED IN CORRESPONDENCE, PARTS
RETURN, OR KITS RETURNED FOR FACTO-
RY SERVICE. It is the factory prerogative to limit
the service facility to one year from date of purchase.
When shipping a unit for service, a note must be
attached specifying symptoms, the name and address
of the sender, and the serial number of the unit. The
amplifier should be securely packed with stuffing in-
side the cover to prevent the tubes from coming out
of their sockets in shipment. It should be placed in a
rugged carton and surrounded with plenty of shock
absorbing packing material. The original carton is
not suitable for shipping an assembled amplifier.
Shipping should be by Railway Express, prepaid;
repaired kits will be returned by Railway Express
collect for shipping and service charges unless these
are prepaid. Parcel post is not a safe method of ship-
ment for assembled units.
Dyna Co. assumes no responsibility or liability for
damages or injuries sustained in assembly or opera-
tion of the DYNAKIT.
MARK IV VOliAGE CHARi
VI rectifler GZ34
V2
&
V3 El34
V47199
Pin
1
1.56
DC
290 DC
2 440 DC
l
140 DC
3
-
432 DC
I
42 DC
<n
<n
4 370 AC
Ql
432 DC
W
--~
5
;l>
-34 DC*
:>
- - ; l >
6
370 AC
(')
(')
1.5
DC
(')
7
-
J
I
8 440 DC
1.56 DC
145 DC
9
140 DC
*This negative voltage must be measured with a
VTVM only.
All measurements on this chart were made with a
VTVM. Other types of meters may give a lower indi-
cation in some cases.
PARiS lISi
Parts of similar type which do not change performance may sometimes be included as a
matter of expediency. This will account for slight variations in value and appearance.
1 Chassis set (including cover and bottom plate)
1 Power transformer-PA-135
1
Output transformer-A-470
1 Choke-C-354
2 Output tubes-EL-34 6CA 7
1 Rectifier tube-GZ-34 5AR4
1 Driver tube-7199
4 Octal sockets
1 Printed circuit assembly-PC-4
1 Filter capacitor (quad
@
525 Volts)
2 Capacitors (50 MFD)
1 Selenium rectifier-Cube
1 Four screw terminal strip
1 Fuse post with rubber washer and mounting nut
1 Fuse 2A
1 Line cord
1 Switch-SPST
1 Input socket
1 Potentiometer-lO,OOO ohms
1 Five lug terminal strip
1 Hank of wire
8
RESISTORS
1 13.5 ohm precision
2 1000 ohm (brown-black-red)
2
10,000
ohm (brown-black-orange)
1
10 ohm (brown-black-black)
1
6800 ohm (blue-grey-red)
1
22,000
ohm (red-red-orange)
1 Solder lug
1
% nut
1
% lockwasher
1
Cable clamp
8 #8 machine screws
8 #8 lockwashers
8 #8 nuts
19 #4 machine screws
16
#4
lockwashers
17
#4
nuts
4 Rubber feet
1 Rubber Grommet
4 Sheet Metal Screws #6
1 Set of instruction,> and warranty card
....