ADEMCO 5775 Інструкція з монтажу - Сторінка 3

Переглянути онлайн або завантажити pdf Інструкція з монтажу для Датчики безпеки ADEMCO 5775. ADEMCO 5775 4 сторінки. Motion detector / transmitter

Normal mounlmg
wllh masked
mwroropllon.
TneceIecIo~ can@
mounted ncxmally al 6 feet ( 1 8m) from the floor Wth the downwacd
pom!mg
pxtion
of Ihe
mirror masked
IMPORTANT!
This ophon IS vahd ontyfor rooms LJP 1015 fl X 15 ft
14 5m
x 4 5m)
m size
1
Mask
the mjrror
using
electrical
of maskmg
tape
as
shown m
diagram
4
2
Mounl Ihe detector usng normal mountmg procedures ala he!ght
o16ff
(1 ftm)
[ 3
Check that no motion is delected
wthin 31~2 ff (f m) of the floor
Using
the
No.
1875PA
Pet Alley
Mirror:
Th6 opl~on mmor can be
used m heu of maskmg
the exmtmg mmor, Refer 10 Its mstallalton
mstructons
for details
To replace the mvror
(f
r--1
11
M-J
1'
~
r
,= ,=
d
II
10
PC BOARD
1
1
2
Spread either of both plasbc
prongs hohlng the wide
angle mirror and remove
the mmr
Inserl one sde of the No
1875PA mmor under a
prong and snap the other
sde under lhe other prong.
Make sure thal the mirror
sides are squarely m their
comer rests and
are held
securely under the prongs
NOTE:
Mirror sudace should
be free of dwt. Iore!gn matter
and fmgerprmls
Use a clean
dry soft cloth to wipe mrror
surfaces if requwed.
b~O-ffi<
(HOLD
MIRROR
IN WE)
Inverted
Mounting
Option:
The detector can be mounted
approximately
3 ff to 35
H. (O 9 – 1m) from the floor m an mverfad
position (PIR window
at
top), wllh spacers attached to the mounting
case. When mslalled in Ibis manner, the portion of the mirror which
normally piowdes a downward
beam of protection now provides an
upward pomlmg beam.
Before mounting
inverted,
note the following:
. Be sure that furniture and other objects do not block the detector's
pattern of protection.
. [f possible. install
a detector so that it is ml directedat ceilingareas
that include heating or air-conditioning
ducts, vents, ce!lmg fans or
lighting fixiures. If these sources of infrared energy or turbalenca
cannal be avo{ded, the upward pamtmg beams must be masked 10
avwcf the possibility of false alarms. To mask the mirror, remove
the fronl cover and apply electrical tapa or masking tape as shown
below:
. Ver#y that the bcation provides a strong radio transmission path to
the Recewer Control as described
earlier.
f, Attach the spacers
to the detector as follows
a.
If
mounhng to flat wall: Assemble the two spacers, one above
the other. and affix the combination to the area of the mounting
case shown in diagram
4.
b.
If mountmg m a corner: affix one spacer to the rear of each of the
corner mowsfmg sales of the mounlmg case. as shown in
diagram 4.
2. Mount the detector mounting case upsidedown
approximately 31/2
feet (1 m) above the floor using the procedure desatbed
earfier.
3. Check that no motion
is detected
within 31/2 feet (1 m) of
the ffaor.
BATTERYCOMPARTMENT
II
1
0
FIA::NY L
o
KNOCKOUTS (3 I
II
SE SURE TO COVER ONLY-WE AREASHOWN
Diagram 4. INVERTEDIPET
ALLEY MOUNTING
5
WALK
TEST
fRefer to lhe Location Test sechon Of Ihe system's Insla":a:ca
Inslructons
for addtlonal
mformallon)
NOTE: The No 5775 requwes a Iwo-mfnute "warmup- period after
applyng ~wer.
1.
2.
3
4.
Remove the front cover from Ihe No 5775 (lo permfl more than
one Vansmlsslon every 3 mmutes). Set und to Pulse Cam! @e
If that aphon is 10 be used.
Pface the system's Receiver
Control inlo Test Mode
Walk mlo the protected area. The Walk Tesl LED will hghl whef
the deteclor senses your motion, and the Recewer Control
WIII
sgnal
the deteclors
alarm Iransmissian
(typically by SCUndmg
audible beeps at Ihe Keypad).
R@ace
cover and verify aperation
at the keypad.
No~e: LED WIII not fght wfthcover
in pface, but ihe transrrufter ID
W
be displayed at the keypad when the detector IS faulted
MAINTAINING
PROPER OPERATION
In onler to maintam the detector in proper working condd}cm. d
IS
Impcaanl that the following be observed
by the user,
1
2
3
Power musl be provided at all limes.
A
9V Alkaline battery shoulc
supply enough power for up to 1-1/2 years" of oparatton normally
A 9V IAhwm battery may last up to 4 years." Refer to the
Specifiitions
section for factors affecting actual banery life m an
installation. However,
a battery must be replaced wnhm 30 days
of a fow battery indication at the Receiver/Controfk
console.
The No. 5775 should never be re-aimed
or relocated wjthwt th~
adwce of the alarm serwce company.
The ohvsical surroundings of the rxolecled
area WIII affect the
Pattern'of protection if c;anged
afier the time of installahon. For
example.
If furniture IS moved. or alr-condltlonmg or acfdwonat
heating is installed, the system may have to be readjusted by the
alarm service company 10 ensure proper prelection.
4.
Nole thal with the No. 5775 front cover in rYace. onlv one alarm
WaJk tests should 'be conducted
fiequent~
(at least weekly) to
mnfirm the proper coverage by each detector. This is accompfishec
by selecting the Test Mode at the Receiver Control's console.
walking through Ihe pratected area, and noting the alarm condit]on
dis@ayed at Ihe ReceiverControl"s
console.
transmission will be transmitted wilhin eve~
three m-inuie period
"UL Listed installations are currently approved for
1
year battery fife c
TROUBLESHOOTING
PROBLEM
M Cites
Into Alarr
Fw NO AcQwenl
Reason.
Wad
Cows@
*S Char@
hsro0asr401
QP-loh
2pafabng
PROBLEM CAUSE
I REMEDY
Rspd
change
m infrad
energykwalsinme
of Iha
pruadad
areas Someot
L&se scurces are elecrnc
or gas haalefs, open Itsmae.
e!ecrnc arcs. w any ebjecls
*may
be parlially m a
zma and can ciwrue
Iaqafature
ra@d~.
Sink or othersmall
animals
are enksnng me afea.
IdwWy
the
sOWcs
d
ma
tnfraad erwgy
w
l-a.
lureCtIarqa
Ra.pmtim
ma
detacror so Ir!althe mm
lsnobrgafrn
apfmaci.sd
Zona,lrthe sourcacarmx
t.s Ilw4ad.
Elirrsnale
all FCSMS e-sty
pores Iorlxrds, cals, Ocgs,
rcdanls, erc Chnlad erssf.
mmstcs If nacassaw
Userhas
re-peirkonad
tvr-
rnlufe
m a
prokclecl
area.
Cam
ueerura
chaqas
In
Iayvul
cm afladcovwsgs
Ra-aimorrekxafesladdauu
aaordirg toinsraltaam
mvwrcos 5s cananrlw
rhedaredwhssnor basn
ranwarad W.
Mounhq
surface
is
unstsb+e.
A
few c@mes
WtliCd
5hifl
can change
raw
Subsrardklly
Urleisnorfecaiwrg
power.
MOLHIl
the
datedorma
eratde
euffaok
Chad
ks
qmplara
barrel-y
Vdrsga.tf!sralnawbme-yfl
necessary,
irusmgikhmm
balterres
sea
Ma kf
urwm
Serrarytkars
bakx
-
Note
for Llthlum Battery Users
The manufacturer has advised us that lithium batteries have a
normal tendency to show low voftage after storage (to prolong shelf
life), due to an increase in capacitance
from non-use.
Once a batlery is put into use, or the battery terminals are shorted
for about 5 secwrds,
preferably
with a 10 ohm wire round resistor (a
minor paper dip vAffsuffii),
the voltage restores to about 9.5 volts,
6