ADEMCO 5808C Інструкція з монтажу - Сторінка 2

Переглянути онлайн або завантажити pdf Інструкція з монтажу для Датчики безпеки ADEMCO 5808C. ADEMCO 5808C 4 сторінки. Photoelectronic smoke/heat detector with built-in wireless transmitter

ADEMCO 5808C Інструкція з монтажу
Figure
2. Remmmendsd
smoke dstedw
location
in moms
with sloped. gabled OT peaked ceilings.
~x-l1,105
.
Inornrr.nuwherecombusuon
pemdes*nnorm.lly
present
suCh,*-"*;
Ing.ngunh*rsthsrearspa*iclesofcombustion
in vshiils exhausts: nuriumacss,
hot w*tw heatat' s. o, gu *paa
heatem.
Install detmcton
at lent 20 iut(6
msten) nrq
bum
Idtchms
l
nd otfwr *mu
wham combustion
pnitsfw
l
n n*lc
mrffy p-t.
* In damp 0rvSty humid Smm. or nSx3 to bathroomS Wth Shown.
The mokture
in humid *i, can enter th* sensing chamber as water
vapor. then cool and condense into dmplsts that cause a nuisance
alarm.
tnstall
detecton
.t feast 5 faet(1.5 maten) *way ' mm
bathmoms.
. In v*ly cold o, veiy hot room* o,
amaaDprating
temperature of
the smoke
detectw is 4BF to 1OO' F (44: to 33%
. In dusty, dbiy, 0, Insact~nfated
&uDust
and Lrf can build up
on th*dBtBC10~s6Bnsingchamberandmakeitov*~sensitiv*.
orcan
Mock openings to the sensing chamber snd keep th* detector fmm
senring smoke.
l
N.a, fmsh .f, Inlet. 0, ,.bn" *
0, *xc.ssf" .lv
dnttv Sm.
Air
mdii.xas,
heaters. fans. and frerh air intakes and m&s
can ddve
smoke *way fmm smoke defeoton. mating the detectas fess *~ectii*.
. Indead tirsp-t**tcpof
apsakedcailingawalVca!li~
int*wct.
DB*d *i, may pmwnf smdw horn reaching *L&to,.
. NU, ft" *mscent
ffgflt flflum*.lm4*ll
detectws at feast 10 feet
(3 meters) away flom such fight fizdums.
WnATTDDDIN
1.
DON' T
PANIC-
escape may depend on cl**, thinking.
2. Get out of the building folIowIng the planned escape ~)ti*s.
if
possible. Do wt stop to dress o, to ooflect anything.
3. Open daon carefully only aft*, feeling them to se* if they *m hot. If
* door is hot. da not open it- follow *n alternate escape route.
4. Kespdosetoth*floor-smok*andhotgapssdss.Sm*the~~gh
(I doth (wet, if possible) and take shoR shallow bmatha.
5. Keep doom and windows of_
unless it is wcossarytoopenthem
fW ercaps.
6. Meet *t you, meeting plats *ftfter l**ting you, building.
7. Call fh* I&
fire department as won as possible fmm outside
the building.
3. N*v*, m-~nt*, * burning building.
For mom lnfwmation about fin safety. contact you, local fire depart-
msnt. They can supply more detailed information about making you,
building as free horn firs hazards as possible *nd about plsnning lo,
escaps in cass of fire.
First, detenine ths best location fw the smoks &t&w;
* location that
provides strong wireless transmission patis and pmpw sunok* &tee
tlhn. A GOOD TRANSMfSStDN PAT" U" ST
SE ESTASLISHED
PROM THE PROPOSED YDUNTtNG LOCATfON BEFORE PERYA-
NENTLY INSTALLING THE DETECTORTo check. perfor" the test
described in th* TESTING TRANSMITTER SIGNAL section of this
manual. TO mount the detector
1. Once *suitable lxatiin
has been determined. install the mounting
bracket on the ceiling or on the wall (if lxal ordinances permit). Use
the two scmwz snd amhon pmvlded.
2. Prior to mwntlng the deteotw to the mwnting bracket. the system
must %am' fh* d*t*ctMs ID. Se* ths PROGRAMMING section fw
the 818~s to follow.
3. Turn the detector in * dockwiss direction in the mounting bracket
until it dioks into place.