Gree 26TTW09HC230V1A Посібник користувача - Сторінка 4

Переглянути онлайн або завантажити pdf Посібник користувача для Кондиціонер Gree 26TTW09HC230V1A. Gree 26TTW09HC230V1A 16 сторінок. Ttw

Figure 3
3. Remove shipping pads inside air conditioner next to
compressor. (See Figure B.)
Figure B
4.
Carefully slide the chassis into the sleeve. Ensure that
the ground wire is not pinched or in the path of the
condenser fan.
5.
Loosen locking plate screw and rotate tab with tab
behind wall case flange (See Figure C) then tighten
locking plate screw.
Locking
Plate
Figure C
6.
To replace front grille:
Remove
shipping
pads
Hook the tabs on the front grille even with the tabs on the case and
snap into place. Replace the screws and filter. Refer to Page 3,
Figure A.
VENT CONTROL AND AIR DIRECTION (See Figure E)
The vent control is located behind the front grille on the right
side of the air discharge area. When set at CLOSE only the air
inside the room will be circulated and conditioned. When set at
OPEN, some inside air is exhausted outside.
Screw Hole
OPEN position
(Mesh end toward back)
4
If outlet is on the left side of the unit, route power cord as
shown in Figure D.
Clamp
Figure D
Tab
Locating
Hole
Figure E
Power
Cord
Grille
Locating
Hole
Screw Hole
CLOSE position
(Mesh end toward front)