Dynamco CYCLOPS PARALYSER 485 Інструкція користувача - Сторінка 6

Переглянути онлайн або завантажити pdf Інструкція користувача для Система безпеки Dynamco CYCLOPS PARALYSER 485. Dynamco CYCLOPS PARALYSER 485 13 сторінок.

PROGRAMMABLE OPTIONS cont'
TURNS DESCRIPTION
5
Siren chirp order
7
Immobilisation dropout time*
9
Arm/disarm flash confirmation**
11
Siren/horn output type
13
Arm/disarm confirmation
15
Voltage drop sensing*
17
Door sensing delay
19
Change PIN Code - refer to page 7
* Changing these options may drain vehicle battery or reduce alarm effectiveness -
installer option only.
** Disabling option #9 means diagnostics is only visible
through status LED.
OVERRIDE
The P485 is overridden in two parts; a high security
lock/switch mounted on the back of the siren and by a
four digit PIN entered through the ignition switch.
Security Switch
!
Locate the siren under the bonnet.
!
Remove the protective black plastic dust cap and
insert the key into the lock. Turn 90 degrees to over-
ride the P485.
This will instantly stop the siren sounding. The P485 is
still armed. The next step shows how to disarm the
P485.
1 FLASH RESPONSE
3 FLASHES RESPONSE
Reversed
Standard
When armed
After 30 seconds
Enabled
Disabled
Pulsed for 30 sec
Constant for 30 sec
Disabled
Enabled
Disabled
Enabled
5 seconds
30 seconds
- Page 6 -