HIDRIA 0310-4-0071 Посібник користувача - Сторінка 8

Переглянути онлайн або завантажити pdf Посібник користувача для Вентилятор HIDRIA 0310-4-0071. HIDRIA 0310-4-0071 8 сторінок. Fan with electronically commutated external-rotor motor

09

PROTECTIVE FEATURES

Short-circuit protection:
The motor and electronic controller are protected against short-circuit by built-in fuse.
Locked-rotor protection:
As soon the rotor is blocked, the motor is switched off electronically an check status in 3 seconds cycle. After de-blocking, the motor will restart
automatically.
Over temperature protection:
Internally connected thermal protection system to protect electronic and motor against over temperature.
Mains under voltage:
If mains voltage falls below the nominal value the motor will keep running with degraded performance. Below 150V, the motor will be switched off
electronically in stand-by mode. When mains voltage returns to correct value, the motor will restart automatically.
In the specific case, the under voltage protection may switch off the fan to stand-by mode, for example, fan running for testing at high pressure
drop and low voltage.
10

EMC

Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to EN 61000-3-2/3
Leakage current: < 3.5 mA acc. to EN 60335
Complying with the EMC standards has to be established on the final appliance, as different mounting situations can result in changed EMC
properties.
0
11

TRANSPORT AND STORAGE

Unit must be transported only in its original package.
When the fan's transported with wood spacer on pallet, take care with the cables (in the situation that fan has connection cables). When
unpacking fans, transported in such a way, grip the fan to protection grill. Do not apply any force for the cable(s).
When transporting fans mounted on final units (apparatus), take care that they are properly secured and don`t touch other devices which are
transported near or on to.
Store the fans in the original packaging in a dry area protected from the weather. Do not store fans in extreme heat and cold.
We recommend a maximum of one year of storage. After a long period of storage we recommend that you inspect the bearings for proper
operation before installation.
Max. permissible storage / transp. temperature: +80°C.
Min. permissible storage / transp. temperature: -40°C.
12

ErP AND ROHS DIRECTIVES

Fan must be mounted in appropriate way to achieve optimal efficiency and life expectancy. We suggest assembling fan in long inlet cone, with fan
blade trailing edge aligned with outlet edge of inlet cone.
Only environment friendly, recyclable materials according to RoHS2 (2011/65/EU) and REACH (EC1907/2006) directive are used in the product.
Disposal must be carried out professionally and environmentally friendly in compliance with regulations applicable in your country.
Design of the product enables simple decomposition of all components. Main components are appropriate marked for easy further handling at
product end-of-life.
0
13

SERVICE ADDRESSES AND ADDITIONAL DATA

Please refer to the homepage at www.hidria.com for a list of our subsidiaries worldwide.
Hidria reserves the right to change any specifications or data without notice.
© Copyright HIDRIA d.o.o., All rights reserved. Document is subject to change without prior notification.
USER'S GUIDE R10 AXIAL FAN , Code: 0000, Iss: 7.02.2020
8 / 8