Hidro-Water ZENIT Посібник користувача та інсталятора - Сторінка 10
Переглянути онлайн або завантажити pdf Посібник користувача та інсталятора для Системи фільтрації води Hidro-Water ZENIT. Hidro-Water ZENIT 15 сторінок. Residential reverse osmosis
ID
SYMPTÔME
CAUSE PROBABLE
Worn post filter.
Plastic or
4
synthetic taste
Contamination.
Unpleasant taste
5
and smell
Air in the system.
White particles in
Excessive inlet pres-
6
sure.
the water
Shut off valve deterio-
rated.
Flushing shut off valve
opened.
The osmosis
system doesn't
Non-return valve dete-
7
stop throwing
riorated.
water away
Excessive inlet pres-
sure.
Non-return valve dete-
riorated.
Excessive inlet pres-
The osmosis
sure.
system starts
up sporadically
8
without water
Leak in some point
consumption
of the system and/or
faucet.
Very little inlet pressu-
re, less than 1 bar.
Low pressure switch in
bad condition.
The osmosis
system stops and
9
Deteriorated non-re-
starts
turn valve.
18
SOLUTION
Replace post filter.
Change the filters, membranes, post filter and
sanitise.
Wait for the air to pass as there's no urgent
problem.
Check the mains water pressure, if it is greater
than 3 bars check the correct working of pressu-
re regulator if it is not so replace it.
Replace shut off valve.
If the flushing shut off valve is always open, re-
place the flushing shut off valve.
Replace non-return valve.
Check the mains water pressure, if it is greater
than 3 bars check the correct working of pressu-
re regulator if it is not so replace it.
Replace the non-return valve.
Check the mains water pressure, if it is greater
than 3 bars check the correct working of pressu-
re regulator if it is not so replace it.
Repair the leak and/or replace faucet.
Bypass the low pressure switch (Danger that
the pump could work without water and break).
Replace the low pressure switch.
Replace the non-return valve.
MA-ES-RO-ZENIT_RO-0236-02_FL_20_V02
8.- MONITORING AND MAINTENANCE CONTROL
DATE:
/
SERVICE MADE
NEXT SERVICE
/
Sediments, GAC y CTO cart. change
/
Membrane change
/
Postfilter change
/
Sanitization
/
Reparation
Name and signature of the authorised technician or distributor:
DATE:
/
SERVICE MADE
NEXT SERVICE
/
Sediments, GAC y CTO cart. change
/
Membrane change
/
Postfilter change
/
Sanitization
/
Reparation
Name and signature of the authorised technician or distributor:
DATE:
/
SERVICE MADE
NEXT SERVICE
/
Sediments, GAC y CTO cart. change
/
Membrane change
/
Postfilter change
/
Sanitization
/
Reparation
Name and signature of the authorised technician or distributor:
DATE:
/
SERVICE MADE
NEXT SERVICE
/
Sediments, GAC y CTO cart. change
/
Membrane change
/
Postfilter change
/
Sanitization
/
Reparation
Name and signature of the authorised technician or distributor:
MA-ES-RO-ZENIT_RO-0236-02_FL_20_V02
/
OBSERVATIONS
/
/
/
/
/
/
OBSERVATIONS
/
/
/
/
/
/
OBSERVATIONS
/
/
/
/
/
/
OBSERVATIONS
/
/
/
/
/
19