Hidro-Water KOBE WS1CI UF Посібник користувача та інсталятора - Сторінка 13

Переглянути онлайн або завантажити pdf Посібник користувача та інсталятора для Диспенсер для води Hidro-Water KOBE WS1CI UF. Hidro-Water KOBE WS1CI UF 19 сторінок. Water conditioning system

12.2.- Problems, causes and possible solutions

ID
PROBLEM
PROBABLE CAUSE
The transformer isn't plugged in.
There isn't any electricity
The display
in the outlet.
1
doesn't
come on.
The transformer's broken down.
The electronic board is damaged.
Power cuts.
The control
2
regenerates at
the wrong time.
The time's not set correctly.
Incorrect regeneration.
Dirty resin.
Incorrect salt dosis.
Incorrect hardness and / or
capacity programming.
Water between
3
regenerations
Water hardness variation.
is hard.
The turbine's rotation
is restricted (meter).
Hardness leaks due to excessive
water use (leaks or consumptions
exceeding the work flow of
the equipment).
The resin has run out.
24
MA-EN-DESCALCIFICADOR KOBE (USR) UF-3004-XX JD18V01
SOLUTION
Plug in the transformer
Repair the power outlet /
electric installation.
Repair transformer.
Replace the electronic board.
Adjust the time.
Realizar una nueva regeneración.
Usar limpiador de resina PQ-1602-10.
Comprobar que hay suficiente sal, el agua de
llenado salmuera es la cantidad correcta y
que, durante la aspiración, se aspira toda.
Repasar programación.
Measure the hardness of the inlet and outlet water.
Reprogramme values and adjust residual
hardness according to the starting point
"8.6.- Adjustment of residual hardness"
Check, clean and/or replace
turbine if required ⓿
Repair pipes and / or accesories with possible
leaks. Adequate consumption or system.
Replace resin ⓿
ID
PROBLEMA
PROBABLE CAUSE
Low water pressure.
Suction and / or drainage
line obstructed.
The system doesn't
4
Injector blocked.
pull brine.
Defective injector.
Air being pulled
in the suction line.
The brine tank
5
is overflowing
Hardness programmed incorrectly
(inlet and residual).
The system uses more
Foreign body in the injector,
6
or less salt than
DLFC or BLFC producing
it should
incorrect flow.
Defective injector, DLFC or BLFC.
The system hasn't regenerated.
There's no
There isn't any salt in
7
softened water
the brine tank.
after regeneration
All of the procedures marked with the symbol
Close the system's inlet valve.
Open the installation's lowest consumption point.
Press the
button for 5 seconds.
REGEN
Wait for the valve to finish positioning itself and press and release the
BACKWASH cycle.
When it's fully positioned, unplug the system from the power supply.
Once the repairs are finished, plug the system to the power supply.
Simultaneously press and hold the
NEXT
Carry out the start-up protocol once again as detailed in section 8.- START UP.
MA-EN-DESCALCIFICADOR KOBE (USR) UF-3004-XX JD18V01
SOLUTION
Increase pressure with a pump.
Take apart and clean ⓿
Take apart and clean ⓿
Replace injector ⓿
Take apart the suction line and
put it back together correctly ⓿
See problem no. 4 ⓿
Measure the inlet's and outlet's
hardness and programme correctly.
Take apart and clean/replace:
Injector, DLFC or BLFC ⓿
Verify possible power cuts.
Add salt and regenerate.
See problem no. 4 ⓿
, involve decompressing the valve as follows:
to go to the
REGEN
and
buttons to go back to the service position.
REGEN
25