All interventions must be carried out by the personnel of the corresponding Technical Assistance Service.
10
If this cable is replaced, remember that the yellow-green earth wire must be at least 40 mm longer than
the live and neutral wires. This will ensure that if the cable is jerked, the last wire to disconnect will be the
earth wire, thus maintaining electrical protection at all times.
3. Protection
The bath is provided with equipotential connection
located on the motor base plate, must be connected to the bathroom's equipotential installation. The
connecting wire may have a section from anywhere between 2,5 mm and 6 mm .
The electrical wiring of the house must include a differential circuit breaker of at least 30 mA, according to
the current regulations of the geographical area where it is installed, and a thermomagnetic circuit
breaker suited to the power consumption of each bath model. (see consumption on the technical
specifications). The latter will be provided with an omnipolar disconnection and with an opening distance
of at least 3 mm. Both circuit breakers must be located outside the protection volumes of the bathroom.
4. Wiring diagrams
On-Off button
5. Technical specifications:
• Supply voltage: . . . . . . . . . . . . . .220... 230V~; 50Hz

WATER PUMP

Wattage rating
Rated current
Protection
Installation manual
between its metallic elements. This connection,
According to plaque colors.
Electronic control box
N L
Level
detector
Water hydromassage pump
650W
2,9A
IP55
2
2
L N
Magnetothermal
circuit breaker
NOT INCLUDED IN THIS SUPPLY
Located outside the bath
protection volumnes (Fig. 3)
Differential
circuit breaker