Table 2. Output Map Designations
I
_
I
_
I
_
I
_
I
I
I
Map designations:
Low Limit
Examples: (The same choices can be used for relay 2)
OPERATION
Display - The TS300 displays the selected temperature (local [ambient] or remote) in either Fahrenheit or Centigrade
as programmed. To check the temperature at a sensor, press the left button for the local sensor or the right button for
the remote probe. The temperature you have requested will flash 5 times and then return to displaying the temperature
of the sensor you have chosen to display.
Alarm - If the temperature at an enabled sensor varies outside either of its mapped limits, the audible annunciator will
sound, if programmed, and the mapped output will switch to its alarm state, but only after the selected delay time has
expired. If the delay time is set to 0 the alarm will be immediate. The maximum delay time is 255 minutes (4 hours, 15
minutes). The output will remain in its alarm state until the temperature returns to within the selected limits as buffered
by the programmed degrees of hysteresis. As long as the temperature remains outside the selected temperature limits,
the display will cycle between the desired display temperature and the name of the limit(s) exceeded.
Silence - The Audible alarm is silenced by pressing either of the buttons. It will remain silenced until the silence timeout
time expires and then it will become audible again. In addition, when the output delay time is in the final 60 seconds the
audible will switch to a fast beep (250mS pulsed), if it has been enabled.
High and Low Temp limits and Alarm Memory - To display the programmed high and low temperature limits, press
and hold both buttons momentarily. The unit will show the programmed limits followed by any alarms in alarm memory.
The TS300 stores the last 8 alarm events. An alarm event is one where the relay output was activated. If delays are used,
and the temperature restored before the delay time expired, it is not considered an alarm and will not be stored in alarm
memory. Alarms are displayed as the limit that was violated. For example LLO for local low limit. The alarms are displayed
most recent to oldest. Alarm memory is cleared when you enter set-up mode or when power is cycled to the unit.
Output 1 - not used
Output 1 - Local Low Alarm
Output 1 - Local High Alarm
Output 1 - Local Low and High
Alarms
Output 1 - Remote Low Alarm
_
-
Output 1 - Remote High Alarm
_
Output 1 - Remote Low and
_
High Alarms
-
_
High Limit
Output 1 - Local and Remote Low
I
_
_
Alarms
-
Output 1 - Local Low and Remote
I
_
High Alarms
_
Output 1 - Local Low and Remote
I
_
_
Low and High Alarms
-
Output 1 - Local High and Remote
I
_
Low Alarms
-
-
Output 1 - Local and Remote High
I
Alarms
-
_
Output 1 - Local High and Remote
I
_
Low and High Alarms
_
_
Output 1 - All Alarms; Local Low
I
_
_
and High and Remote Low and
High
Both Low
& High Limits
- 3 -