WARNING: Consult your doctor if there is reason to doubt your fi tness to safely absorb the shock from a fall
arrest. Age and fi tness seriously affect a worker's ability to withstand falls. Pregnant women or minors must not
use DBI-SALA Vertical Lifelines or subsystems.
4.1
BEFORE EACH USE: Inspect the components of the Pole Anchor System according to the Inspection
Guidelines (Section 5.2). Inspect the Full Body Harness according to the manufacturer's instructions.
4.2
USE: Figure 17 illustrates Safl ok Pole Anchor Systems with bottom or top anchorage. Operating procedures
for either system are as follows:
WARNING: If the Safl ok Pole Anchor System is subjected to fall arrest forces, it should be removed from
service and destroyed.
Step 1.
Don a Full Body Harness: A Full Body Harness equipped with a back Dorsal D-ring (17D)
should always be used with the Pole Anchor System. Don the harness per the manufacturer's
instructions.
Step 2.
Attach the the Rope Grab Shock Absorber to the Full Body Harness: The Rope Grab (17F)
is equipped with an attached Shock Absorber (17E). Secure the Carabiner on the end of the
Shock Absorber (17E) to the Dorsal D-ring (17D) on the Full Body Harness.
Step 3.
Attach the Rope Grab to the Vertical Lifeline Rope: Figure 18 illustrates installation of the
Rope Grab on the Vertical Lifeline Rope. Procedures are as follows:
A.
Ensure the Rope Grab is in the 'UP' position with the arrow (18A) on the the Rope Grab pointing
toward the top of the wood pole.
NOTE: The Rope Grab incorporates a Gravity-Lock Pin which slides out of the Locking Pin, preventing
the Lifeline Sleeve from mating with the Rope Grab Cam if the Rope Grab is not held upright.
B.
Push the Opening Lever (18B) down until it reaches the bottom of the groove (18C) and then
slide it inward until the Release Button (18D) is completely pressed and covered by the Opening
Lever.
C.
Pull the Lifeline Sleeve (18E) and Locking Cam (18F) halves apart until the Rope Grab is fully opened.
D.
To install the Rope Grab on the Vertical Lifeline Rope, raise the Locking Cam (18F) to the 'UP'
position, align the rope inside the Lifeline Channel (18G) and close the hinged Rope Grab
halves.
Closing the Rope Grab halves releases the Opening Lever (18H) from the open position and
slides the Lock Pin (18I) into the Lock Ring at the top of the Lifeline Sleeve. The Opening Lever
should be resting at the top of the groove against the Lifeline Sleeve.
E.
Test the Rope Grab for proper operation by pulling down on the Locking Cam (18J). The
Rope Grab should lock onto the Vertical Lifeline Rope and prevent descent down the lifeline
once the Cam is engaged.
Step 4.
Climb up and down the Wood Pole with the Rope Grab sliding up or down the
Vertical Lifeline Rope as you ascend or descend:
A.
Using the Shock Absorber (17E) connected to the Rope Grab (17F), pull up slightly on the
Rope Grab's Locking Cam (18J) to release it from the locked position. Always keep a minimum
of 12 feet (3.7 m) of rope below the Rope Grab to accommodate locking distance and fall
clearance.
Figure 18 - Attaching the Rope Grab to the Vertical Lifeline Rope
A
B
D
C
E
F
G
8
J
I
H