BALANCED FLOATING OPERATION
Jensen
Output
Transformer
BALANCED GROUND-
REFERENCED OPERATION
Jensen
Output
Transformer
Figure 5: Ground/Unbalance switch operation.
Note: T
he shorting link between chassis ground and signal ground should be left installed, unless another
grounding scheme is used.
1/4 Inch Anchor Bolt
We have provided a 1/4" anchor bolt on the rear panel of the 786 to aid in securing the unit in your
rack. Since the 786 is a heavy unit, we recommend securing the 786 to a rear rack rail to avoid unnec-
essary stress on the front panel and front rack rails of your rack. The anchor bolt provides no electrical
or audio benefit to the 786, and no grounding or electrical wires should be connected to it.
AC Power Switch
Located beside the AC Power connector, the AC Power switch turns the 786 ON and OFF. When the
switch is in the DOWN position, revealing the red portion of the switch, the AC power to the 786 is ON.
When the switch is in the UP position, no AC power is being supplied to the 786, regardless of other
power connections.
AC Power Connector
The AC Power connector is a standard IEC 320 power inlet receptacle, for use with any IEC-type power
cord (included with the 786). Connect this cable to any 50Hz or 60Hz AC power source of the correct
line voltage for your area. Make sure this voltage is also correct for the voltage marked on the back of
the 786. Always make AC power connections with the AC power switch in the OFF position (see above).
The 786 consumes a maximum power of 50 watts.
Warning:
Be sure to verify both your actual line voltage and the voltage for which your 786 is wired, as indi-
cated on the back panel of the unit. Connection to an inappropriate power source may result in exten-
+
Chassis
1
2
Ground
3
-
¨
10k 1W
Ground Switch open
Unbalance Switch open
GND
Switch
Chassis
Ground
+
Chassis
1
2
Ground
3
-
¨
10k 1W
Ground Switch closed
Unbalance Switch open
GND
Switch
Chassis
Ground
controls
786
UNBALANCED FLOATING OPERATION
+
Chassis
Ground
-
Jensen
¨
Output
Transformer
Ground Switch open
Unbalanced Switch closed
Switch
(6dB drop in output level)
Chassis
Ground
UNBALANCED GROUND-
REFERENCED OPERATION
+
Chassis
Ground
-
Jensen
¨
Output
Transformer
Ground Switch closed
Unbalance Switch closed
Switch
(6dB drop in output level)
Chassis
Ground
Operating
1
2
3
GND
1
2
3
GND
9