Autonics MP5M-N Series Посібник з експлуатації - Сторінка 5
Переглянути онлайн або завантажити pdf Посібник з експлуатації для Вимірювальні прилади Autonics MP5M-N Series. Autonics MP5M-N Series 6 сторінок. Thumbwheel switch multi pulse meters
■ F9: length measurement 1
Measure and display the number of input A pulses during input B ON.
Length measurement 1 = P × α
Display value Display unit
Quantity [EA]
(default)
Length
mm
measurement
1
cm
m
Input A
1
2
3
4
5
6
1
2
Input B
ta
Hold
Display
6 × α
• ta, tb: Return time (≥ 20 ms)
■ F10: interval
Measures and displays the number of input A pulses from input B ON to the next
ON.
Interval
= P × α
Display value Display unit
Quantity [EA]
(default)
mm
Interval
cm
m
Input A
1
2
3
4
5
1
Input B
ta
Hold
Display
• ta: Return time (≥ 20 ms)
■ F11: accumulation
Measures and displays the counted value of input A pulses.
Accumulation = P × α
Display value Display unit
Accumulation Quantity [EA]
• Operation
① Counts the number of input A pulses.
② Input B is an enable input signal. During ON, the quantity and display value of input A
will be held, and during OFF input A will be recounted.
③ When RESET input is ON, the integrated counted value will be reset to "0"
Input A
1
2
3
4
5
6
Input B
RESET
Display
0
1
2
3
4
5
6
• α = display value for 1
■ F12: addition / subtraction-individual input
Displays the counted value from added input A pulses and subtracted input B
pulses. When there are two inputs simultaneously, it will not count.
Add / Sub
= input A × α - input B × α
(individual)
Display value
Display unit
Addition /
Subtraction
Quantity [EA]
(individual)
Input A
Input B
RESET
Display 0
1
2
3
2
0
1
• α = display value for 1
• P: number of input A pulses
• α: prescale value
Input A
Input B
Photoelectric sensor
MP5
1
2
3
4
tb
2 × α
4 × α
• P: number of input A pulses
• α: prescale value
MP5
Photoelectric sensor
2
3
4
1
2
3
5 × α
4 × α
• P: number of input A pulses
• α: prescale value
1
2
3
4
0
1
2
3
4
• α: prescale value of input A
MP5
Photoelectric
sensor
Input A
(add)
2
3
2
1
■ F13: addition / subtraction-phase difference input
When input A is Low, counting is added to the low of input B.
When input A is Low, counting is subtracted from the high of input B.
Add / Sub
(phase difference)
Display value
Addition /
Subtraction
(phase difference)
Input A
Input B
RESET
0
Display
■ F14: length measurement 2
Measures and displays the number of pulses from input A until the value of input B
reaches the setting value.
Length
measurement 2
Display value
Length
measurement 2
• If input A and input B are ON during initial power supply, it will not count and only count the
number of rising edge.
• Display value is renewed depending on the P2-9. Display cycle.
(e.g.: input B = 4)
Input A
Input B
RESET
0
1
Display
Display
01)
01) When P2-9 Display cycle is OFF, it will maintain the quantity of input A until the value of
input B reaches the setting value of P2-10 Input B setting value (INB).
MP5
Input B
(sub)
= Detects position and speed
using A and B phases of
encoder outputs as input.
Display unit
Quantity [EA]
1
2
3
2
1
0
1
2
0
• P: number of input A pulses
= P × α (until the setting
value of input B)
• α: prescale value
Display unit
Quantity [EA]
1
2
1
2
3
4
1
2
3
4
0
1
2
3
4
5
6 7
0
1
0
Input A
Input B
MP5
2
3
2
3
4 5
7