Mode Setting
[2-stage setting model]
→
[MODE]
Display value switching
→
[◀]
Preset value change mode
→
Parameter group
[MODE] 3 sec
RUN
Function setting check mode
→
[▲] 1 sec
[RESET] or
→
terminals input
01) Use [MODE], [▲] key to check the parameter setting.
Counting value display part: Displays setting item.
Setting value display part: Displays setting content.
02) The output is OFF.
Preset Value Change Mode
Even if the mode of preset value change, input operation and output control will continue.
The preset value could be set to 0 and the output of 0 preset value occurs.
• Defaults: SET1 = 1000, SET2 = 5000
• The preset value could not be set to 0 depending on the output operation mode.
(When setting to 0, the value of setting value display part flashes 3 times.)
• Counting value display part: Displays present value,
Setting value display part: Displays preset value.
• Setting sequence: SET2 > SET1 > TOTAL* > TOTAL COUNTER RESET*
1. Press [◀] key to enter 2-stage preset value change mode.
2. Use [◀], [▲] key to set 2-stage preset value.
3. Press [MODE] key to enter 1-stage preset value change mode.
4. Use [◀], [▲] key to set 1-stage preset value.
5*. Press [MODE] key to confirm the total counter setting.
6*. Pressing the [MODE] key returns to the operation mode, and pressing the [RESET] key
resets the total counter value.
* appear when the 2-stage preset setting model operates as a counter.
Display value switching of 2-stage preset setting model
■ Counter
Whenever pressing the [MODE] key, each 1-stage preset value, 2-stage preset value, total
counter value displays consecutively.
■ Timer - Manual
Whenever pressing the [MODE] key, the setting value display part displays 1-stage preset value,
2-stage preset value in turn.
• In case of output operation mode: OND, OND.1, OND.2, OND.3, it is available.
■ Timer - Auto
1-stage / 2-stage preset value are automatically switched and displayed.
• In case of 1-stage / 2-stage preset setting model & output operation mode: FLK, NFD, NFD.1
or
2-stage preset setting model & output operation mode: INT.2, it is available.
Auto
[MODE]
[MODE] 3 sec
[MODE] 1 sec
01)
Reset
Auto
02)
Parameter Setting
• Some parameters are activated / deactivated depending on the model or setting of other
parameters. Refer to the description of each parameter.
→
• Counter counting / timer progress and output control are performed even when entering the
function setting mode from run mode.
→
• [MODE] key: Saves current setting value and moves to the next parameter.
[◀] key: Checks fixed value / Changes setting digits.
[▲] key: Changes setting values.
→
RUN
■ Counter parameter group
→
Parameter
Mark
Counter /
→
C1-1
Timer
01)
Input
C1-2
operation
mode
01)
Output
C1-3
operation
mode
01)
Max.
Counting
C1-4
speed
01) 02)
OUT2
C1-5
output
time
01) 04)
OUT1
C1-6
output
time
01) 04)
OUT
C1-7
output
time
01) 04)
Counting
value /
C1-8
preset value
decimal
point
01)
Min. RESET
C1-9
time
02)
Input logic
C1-10
02)
Prescale
C1-11
decimal
point
01)
Prescale
C1-12
value
01) 06)
Total
C1-13
counter
Start Point
C1-14
value
01)
Memorize
C1-15
counting
value
C1-16 Key LOCK
01) When the setting value of the parameter is changed, all outputs are OFF and reset the current value when
returning to the RUN mode.
02) In case of CX6□-□P□F model, C1-4 Max. Counting speed = 20 cps, C1-9 Min. RESET time = 25 ms, C1-10 Input
logic = NPN are fixed, so these parameters are not displayed.
03) C1-3 Output operation mode: in case of D, 1, 30, 300, 1k cps selectable.
C1-4 Max. counting speed: 5k, 10k cps & C1-3 Output operation mode: When D is set, the max. counting speed is
automatically changed to 30 cps.
04) In case of 1-stage preset setting model, C1-6 OUT1 output time is not displayed, C1-5 OUT2 output time is
displayed as OUT.T.
05) For other output operation modes, Hold is fixed.
06) In the case of retained (hold) output, it displays the over value of prescale value.
When SV is n multiplied by prescale value and the display value after hold output mode and SV are different, the
prescale value is not the 1/n time of SV.
Defaults
Setting range
COUNT: counter,
TIME: timer
C-T
COUNT
[CX6□-□P□ model]
UP, UP-1, UP-2, UP-3,
DN, DN-1, DN-2, DN-3,
UD-A: command input ,
UD-C
UD-B: individual input,
UD-C: phase difference input
InM
[CX6□-□P□F model]
UP, UP-1, UP-2, UP-3,
DN, DN-1, DN-2, DN-3,
UD-A
UD-A: command input
F F, N, C, R, K, P, Q, A, S*, T*, D*
OUtM
[CX6□-□P□ model]
30, 300, 1K, 5K, 1 cps
• Max. counting speed is when duty ratio
of INA or INB input signal is 1:1. It is
CPS
30
applied for INA, or INB input as same.
OUT2
HOLD
[2-stage preset setting model]
0.01 to 99.99 sec, Hold
• When 10
digit is flashing, press [◀]
1
key once and Hold appears.
OUT1
0)10
[1-stage preset setting model]
0.01 to 99.99 sec, Hold
• When 10
digit is flashing, press [◀]
1
OUtT
HOLD
key once and Hold appears.
------, -----.-, ----.--, ---.---, --.----, -.-----
• Set the decimal point of the number
displayed on the front of the product
DP ------
regardless of the prescale value.
[CX6□-□P□ model]
1, 20 ms
RESET
20
[CX6□-□P□ model]
NPN, PNP
SIG
NPN
-.-----, -----.-, ----.--, ---.---, --.----
• Set the decimal point of the prescale
value applied to the count value
regardless of the decimal point
displayed on the front.
SClDP -.-----
• It can not be set smaller than the
digits of C1-8 Counting value /
preset value decimal point.
SCL !00000 0.00001 to 99999.9
[CX6□-□P□ model]
ON, OFF
• When set to ON, the total counter
TOTAL
counting value counts up to 999999
OFF
and counts cycles from 0.
START 000000 0.00000 to 999999
CLR: Resets counting value when
power is off.
REC: Memorizes counting value at the
DATA
moment of power off.
CLR
(memory retention)
L.OFF: Unlock key LOCK
LOC.1: Locks [RESET] key
LOC.2: Locks [◀], [▲] key
LOCK
lOFF
LOC.3: Locks [RESET], [◀], [▲] key
Display
condition
-
-
-
*C1-2 Input
operation
mode: UD-A,
UD-B, UD-C
C1-3 Output
operation
mode
03)
C1-3 Output
operation
mode:
C, R,
K, P, Q, A
05)
C1-3 Output
operation
mode:
F, N,
C, R, K, P, Q,
A
05)
C1-3 Output
operation
mode:
C, R,
K, P, Q, A
05)
-
-
-
-
-
-
C1-2 Input
operation
mode: UP,
UP-1, UP-2,
UP-3, UD-A,
UD-B, UD-C
&
C1-13 Total
counter:
OFF
-
-