This generator has three main LED indicators to indicate to the operator
various conditions as follows:
1. Low oil indicator (Fig L)
The low oil indicator light (7) is a yellow LED and will illuminate when the
oil level of the generator is too low. The generator will stop operating
within 10 seconds if the yellow light comes on. If the oil level is on the
extreme low level the LED may flash on and off quickly and the generator
will run unevenly. The yellow LED will illuminate when the generator is
being attempted to start if the oil is low, i.e. when the cord is being pulled,
the yellow LED will glow if there is insufficient oil. In this condition, the
generator will not start. In this condition you need to add oil for the
generator to operate.
2. Load Status indicator (Fig M)
The red load status indicator light (8) advises the operator that a fault
has been detected and the power supply to the control panel has been
interrupted. When the red load status indicator is operating red, there is NO
240Va.c. available to the control panel.
When the engine is running the load status indicator light (8) flashes under
the following conditions:
a. Flashing once indicates low voltage protection, caused by the engine
rotation speed not meeting the specified reqauirements.
b. Flashing twice indicates the engine is overheated, caused by high
temperature.
c. Flashing 3 times indicates overload protection caused by an excessive
electrical overload.
d. Flashing 4 times indicates there is an electrical problem most likely caused
by a short circuit.
In any of the above instances, when the red load status indicator light
(8) turns on, the power supply to the control panel will be disconnected
automatically.
NOTE: The engine must be stopped and the issue resolved before the
power supply will be restored.
18
e-mail: [email protected]
MODEL: №. INF3800A • 52299
3500W Digital Inverter with Pure Sine Wave
AFTER SALES SUPPORT
1800 909 909
(toll free)
3500W Digital Inverter with Pure Sine Wave
L.
3. Power Supply indicator (Fig N)
The power supply indicator light (9) is
a green LED. It will only display green
when there is a 240V output available,
thus the generator must be operating.
This indicator will remain on when
the generator is operating and has
240Va.c. available to the control panel,
with or without appliances connected
to the AC sockets (12).
In an overload condition, there is no
240Va.c. available to the panel so the green indicator will not operate.
Preparing the Generator
It is important to check the generator before you commence operating
the unit.
IMPORTANT. Ensure that the engine has oil. When leaving the factory, this
generator has NO OIL in the engine.
NOTE. The engine will not start if the generator has no oil.
Checking the Engine Fuel
IMPORTANT: Fuel goes off after about 3-4 months. If you find your generator
does not start, first change the fuel in the tank with newly purchased fresh
unleaded fuel. Do not use ethanol based fuels.