909 52299 Посібник користувача - Сторінка 19
Переглянути онлайн або завантажити pdf Посібник користувача для Інвертор 909 52299. 909 52299 20 сторінок. 3500w inverter generator with pure sine wave
Troubleshooting
Trouble
Possible cause
1. Low on fuel or oil content
Engine will not start
2. On/Off switch (4) in "Off" position
3. Faulty spark plug (23)
4. Choke lever (19) in wrong position
5. Fuel shut-off valve in closed position
6. Unit loaded during start-up
7. Spark plug (23) wire loose
8. Old fuel in carburetor
1. Faulty receptacle
No electrical output
2. Overload has been triggered
(red Overload light on).
3. Faulty power cord
4. Master 240Va.c switch (13) turned off.
1. Overload
Repeated overload
2. Faulty cords or equipment
1. Generator overloaded
Generator overheating
2. Insufficient ventilation
1. Check oil level
Generator keeps stopping,
or is operating rough
2. Generator not sitting on flat
and level surface
3. Motor needs to be cleaned of carbon
For other issues not covered in this chart, please call Customer Service on 1800 909 909.
34
e-mail: [email protected]
MODEL: №. INF3800A • 52299
3500W Digital Inverter with Pure Sine Wave
Suggested remedy
1a Fully fill tank. Ensure fuel is fresh
1b Ensure oil is at the the correct level.
Refer page 20-21 of this manual.
1c Ensure the generator is horizontal and
not on an angle
1d Turn Off the fuel tap / lever (26).
Loosen the carburettor drain screw.
Allow the fuel in the carburettor bowl
to totally drain. When the fuel has
stopped draining, open the fuel tap /
lever (26) on the tank and fuel starts
running out of the carburetor drain. If
so, tighten the screw on the drain and
allow the carburetor to fill with petrol.
1e If the fuel from the tank does not pass
through the carburetor drain above,
turn off the fuel tap / lever (26) and
clean the fuel filter in the bottom of the
fuel tap. Refer to page 30-31.
2. Press the On/Off switch (4) to the 'On'
position as indicated by an "I" .
3. Replace or clean spark plug (23)
4. Adjust choke lever (19) accordingly
Refer to page 22.
5. Open fuel shut-off valve
6. Remove load from unit
7. Attach wire to spark plug (23)
8. Fuel will deteriorate in the carburetor
fuel bowl very quickly. Open the drain
screw in the bowl of the carburetor until
fresh fuel runs through.
1. Have service centre replace receptacle
2. Remove all appliances. Stop the
generator, and restart. Reconnect
appliances but with reduced load.
3. Have an electrician replace cord.
4. Check the master 240Va.c switch (13)
is ON.
1. Reduce load
2. Check for damaged, bare, or frayed
wires on equipment. Replace.
1. Reduce load
2. Move to adequate supply of fresh air
1. Add oil so oil is at the correct level.
Refer page 20-21 of this manual.
2. Move generator to a level and
flat surface
3. Remove, check and clean spark
arrestor (11) if needed.
Remove, clean or replace spark plug (23)
AFTER SALES SUPPORT
1800 909 909
(toll free)
3500W Digital Inverter with Pure Sine Wave
Specifications
AC output:
240Vac ~ 50Hz
Rated power:
3200W
Peak power:
3500W
Phase:
Single
Power factor:
cosφ =1
Displacement:
182cc
Motor:
4 stroke
No load speed:
3000 RPM
Approximate Generator
Run time:
(Hours per full tank)
Full Load:
5.5 Hours
50% Load:
9 Hours
25% Load:
12 Hours
Fuel tank capacity:
10.5L
Fuel type:
Unleaded
Oil tank capacity:
600ml
Oil type:
4 Stroke (SAE 10W-30)
Net weight:
31kg
(with wheels and handle)
Spark plug:
NGK BPR6ES
Product Dimensions:
(without wheels or carry handle) 52cm x 41cm x 46cm (L x W x H) +/- 10%
Noise rating:
69 dB (A) (taken at 7.5 metres)
You must wear ear protection at all times.
This product complies with:
Safety – AS 2790-1989/Amendment 1-1989
CISPR12:2009 ed6
AFTER SALES SUPPORT
1800 909 909
(toll free)
Specifications
35
e-mail: [email protected]
MODEL: №. INF3800A • 52299