8.Temperature Calibration
8.1 Press "set" button for 4 seconds to
enter into second level menu.Display
as below.(see figure 8.1)
8.3 press "up" and "down" button to make
temperature calibration.
if temperature on heater is higher than
circuit board shows,pls lower the Pb
value.
Example:
Heater temperature:190C
Circuit board temperature:185C
Pls set Pb Value at ( -5 )
8.1
8.2 Press "set" button to select "Pb" mode
(See figure 8.2)
8.4 Press "set" button 4 seconds to quit.
If temperature on heater is lower than
circuit board shows,pls raise the Pb value.
Example:
Heater temperature:185C
Circuit board temperature:190C
Pls set Pb Value at ( +5 )