Pour the cleaning liquid from the ultrasonic cleaning tank
back into the original bottle and wipe the ultrasonic
cleaner with a soft dry cloth.
Wipe the machine table top with a dry soft cloth.
In order to avoid volatilization, all the test solution in the
fuel tank should be cleaned out. If it can be used
continuously, it should be stored in a safe place. If it is
dirty, it can not be used any more, dispose it according
to relevant regulations.
Operation
Ultrasonic Cleaning
Ultrasonic cleaning is the penetration and cavitation shock
wave generated by the ultrasonic wave propagating in the
medium. The object with complex shape, inner cavity and
fine pores is strongly cleaned to completely remove the
stubborn carbon on the injector.
:
Method and Steps
Turn on the power of the ultrasonic cleaner. Plug the end
of the power cord into the socket of the washer and the
other end into the power outlet.
Place the outside cleaned injector on the cleaning bracket
in the cleaning tank.
Add an appropriate amount of cleaning liquid or special
ultrasonic
cleaning
liquid
machine. Generally, the cleaning liquid can be immersed
in the nozzle needle valve for about 20mm.
to
the
ultrasonic
cleaning
11
Insert the injector pulse signal line into the injector
separately.
Turn on the ultrasonic power switch.
Select the ultrasonic cleaning function in the control panel,
then set the time (the default system time is 10 minutes),
and press the [Run] key.
At the end of this work, the system will automatically
stop and beep with a buzzer. At this time, the ultrasonic
power switch can be turned off.
Take the nozzle from the cleaning tank and clean the
cleaning liquid with a soft cloth to prepare for the next
job.
Note: In the case that the ultrasonic cleaning bath is not
equipped with ultrasonic cleaning agent, it is forbidden to
open
the
ultrasonic
system,
equipment will be easily damaged.
Uniformity/
Sprayability Test
The uniformity test is to detect whether the difference
between the injection quantities of the injectors meets the
requirements or within the specified error range under the
same working conditions of the injectors on the same vehicle.
This inspection can reflect the electrical characteristics of the
injector, the change in the diameter of the nozzle, and the
combined effects of the plugging and other factors on the
injector. The atomization test is to detect the atomization
performance
of
the
injector
condition and atomization of the injector when working under
certain working conditions.
otherwise
the
ultrasonic
by
observing
the
injection