PSXX-AR & PSXX-ARSC Manual
J1 Input Power Connector
J1-1
DCC Power Input A [from DCC Booster]
J1-2
DCC Power Input B [from DCC Booster]
J2 Output Power Connector
J2-1 Switched DCC Power Output A ["normal" polarity]
J2-2 Switched DCC Power Output B ["normal" polarity]
J2-1 Switched DCC Power Output B ["reverse" polarity]
JP1 Program Jumper
JP1-1 & JP1-2 Place jumper on pins 1 & 2 for Programming
JP1-2 & JP1-3 Place jumper on pins 2 & 3 for Operations
J4 Block Occupancy & Block Shorted
J4-1: GND Manual OFF J2 Output -
J4-2: Input Manual OFF J2 Output +
J4-3: Output Block Shorted Emitter
J4-4: Output Block Shorted Collector
J4-5: Output Block Occupied Emitter
J4-6: Output Block Occupied Collector
J5 Status Outputs [Remote]
J5-1: +Remote D23 [RED] Anode
J5-2: - Remote D23 [RED] Cathode
J5-3: + Input Photocell
J5-4: - GND Photocell
J6 Trip Current Settings by Jumpers
No Jumpers = 1.8 amperes [default]
J6-1 to J6-2 = 2.7 amperes
J6-3 to J6-4 = 0.9 amperes
J6-1 to J6-2 & J6-3 to J6-4 = 3.6 amperes.
Set trip current using either wire Jumpers or Programming CV 49: NOT BOTH
J7 Auto/Manual Reset & Powering LEDs
J7-1: +5V Output for powering external LEDs, etc. in conjunction with Block Occupied or Block Shorted outputs.
Maximum load should be less than 25mA.
J7-2: GND Return connection for J7-1 5V output
J7-3 to J7-4 with wire Jumper: Manual Reset [open to reset]
J7-3: Auto/Manual Reset
J7-4: GND
The user can install a normally closed push button switch in series with the jumper.
o
Open the switch to reset the PSXX or send an accessory ON command to the PSXX on-off command address
o
J7-5: Over-current Indication Output
J7-6: GND
J7-5 to J7-6 output mirrors D24.
o
J9 TBD
J10 DCC Power In Remote LED Indicator Output
J10-1: +Remote D12 [Green] Anode
J10-1: - Remote D12 [RED] Cathode
J11 Track Power On Remote LED Indicator Output
J11-1 & J11-2 Output is on any time that D20 (GREEN) is on indicating Reverse phase output
This output should ONLY be connected to an isolated LED.
J11-3 J11-4 Output is on any time that D11 (GREEN) is on indicating Normal phase output.
This output should ONLY be connected to an isolated LED.
J11-1: Remote D11 Green Remote Track On Reverse cathode -
J11-2: Remote D11 Green Remote Track On Reverse anode +
J11-3: Remote D20 Green Remote Track On Normal cathode -
J11-4: Remote D20 Green Remote Track On Normal anode +
J12 Stall Motor Output
J12-1: Stall Motor #1 +
J12-2: Stall Motor #1 –
J12-3: Stall Motor #2 +
J12-4: Stall Motor #2 -
J13 Snap Coil Output
Kato 2 wire switch machines use pins 1 & 4
Peco/Atlas 3 wire switch machine will use pins 1,2,4
J13-1: Pulse Motor Coil 2/Coil -
J13-2: Pulse Motor Coil 1/2 V+
J13-3: Pulse Motor Coil 1/2 V+
J13-4: Pulse Motor Coil 1/Coil -
Rev: A Software Rev: A
3