INSTRUCTIONS: QUASAR Cod: DYN 48.1.07
Fecha: 04/12/2017 Revisión: 07
REMOTE OPERATION
The governor incorporates a remote jamming system to check for the correct interlocking of the governor and the
subsequent jamming of the safety gear.
It is basically made up of a remote electromagnetic interlocking system that may be operated from the machine room.
There are three versions available for the installer to choose at his/her convenience.
24 V DC (Direct current) powered coil. A 1.2 A current must be guaranteed.
48 V DC (Direct current) powered coil. A 0.5 A current must be guaranteed.
190 V DC (Direct current) powered coil. A 0.16 A current must be guaranteed.
Note: In any case, only a few seconds are required to interlock the governor. After operation, the power feeding the
coil is to be cut so as not to excessively overheat it. That is the reason why it is recommended to operate the system
via a pushbutton.
The figure displays both the device and its location within the unit (1)
TEST PULLEY
As an option, the Quasar governor may be supplied with a test pulley. The figure on the right displays its location at
the rear of the main pulley.
To test jamming, move the rope in the main pulley to the test pulley; this way, the governor will interlock at the rated
speed of the lift, thus jamming the safety gears.