Highland HP6IFC-2 Інструкція з використання та догляду - Сторінка 15
Переглянути онлайн або завантажити pdf Інструкція з використання та догляду для Варильна поверхня Highland HP6IFC-2. Highland HP6IFC-2 20 сторінок. Induction ceramic hob
INSTALLATION INSTRUCTIONS
The installation comes under the exclusive responsibility of service.
The installer must respect the legislation and the standards enforce in his home country.
How to stick the gasket:
The gasket supplied with the hob avoids all infiltration of liquids in the cabinet.
Installation has to be done carefully, in conformity of the following drawing.
Fitting - installing:
The cut out sizes are:
Ensure that there is a distance of 50 mm between the hob and the wall or sides.
The hobs are classified as "Y" class for heat protection. Ideally the hob should be installed
with plenty of space on either side. There may be a wall at the rear and tall units or a wall
at one side. On the other side, however, no unit or divider must stand higher than
the hob.
The bench top or the support in which the hob is to be fitted, as well as the edges of
furniture, the laminate coatings and the glue used to fix them, must be able to resist
temperatures of up to 100 °C.
The mural rods of edge must be heat-resistant.
Do not install the hob to the top of a non-ventilated oven or a dishwasher.
The underside of the hob has a casing space of 20 mm to ensure a good air circulation of
the electronic device.
If a drawer is placed under the unit, do not put flammable objects (for example: sprays) or
not heat-resistant objects inside.
To protect the cut out edge, apply a coat of varnish or special sealant. Particular care must
be given to applying the adhesive joint supplied with the hob to prevent any leakage into
the supporting furniture. This gasket guaranties a correct seal when used in conjunction
with smooth work top surfaces.
The safety gap between the hob and the cooker hood placed above must follow the
guidelines of the hood manufacturer. In case of absence of instructions, respect a distance
minimum of 760 mm.
The connection cord should have no mechanical constraint, for example, from the action
of the drawer.
Stick the gasket (2) two millimeters from the
Reference
HT3IFC-2
HP4IFC-2
HP6IFC-2
external edge of the glass, after removing
the protection sheet (3).
Cut-size
800 x 330 mm
560 x 490 mm
750 x 490 mm
15