adept technology T6100 Інструкція з експлуатації - Сторінка 8
Переглянути онлайн або завантажити pdf Інструкція з експлуатації для Терморегулятор adept technology T6100. adept technology T6100 9 сторінок.
Також для adept technology T6100: Інструкція з експлуатації (10 сторінок)
No.
Name
Default
1
Room temp calibra�on
0.0°C
2
Floor temp calibra�on
0.0°C
3
An�-frozen func�on
ON
4
An�-frozen temp
5.0°C
5
Sensor selec�on
01: Floor sensor
6
Floor temp limit
30.0°C
00: °C
7
Temp unit
8
Output delay
00: 00s
9
Temp devia�on
01: 1.0°C
10
Reverse output
00: OFF
11
Schedule
01: 5+1+1
12
Adap�ve func�on
01: ON
13
Reset
00: No
11
Ranges
-5.0°C -- 5.0°C
-5.0°C -- 5.0°C
OF(OFF)
ON
5.0°C -- 15.0°C
00: Room sensor
01: Floor sensor
02: Both sensors
20.0°C -- 50.0°C
00: °C
01: °F
00: 00s
01: 30s
02: 60s
03: 90s
00: 0.5°C
01: 1.0°C
02: 2.0°C
03: 3.0°C
00: OFF
01: ON
00: 7
01: 5+1+1
00: OFF
01: ON
00: No
01: YES
1. Room temp calibra�on:
Calibrate the temp detected by room sensor.
2. Floor temp calibra�on:
Calibrate the temp detected by floor sensor.
3. An�-frozen func�on:
This op�on allow you to bring warmth to your plant and pet with a lower temp.
displays when you turn off the thermostat.
In hydronic hea�ng system, it will keep away from freezing.
4. Sensor selec�on:
00 Room sensor: Run by room sensor.
01 Floor sensor: Run by floor sensor.
02 Both sensors: Run by room sensor with floor temp limit.
5. Floor temp limit:
If you choose both sensors, floor temp limit must be set to protect floor.
6. Temp unit:
°C and °F can be selected.
7. Output delay:
This op�on help you avoid inadvertent opera�on on hea�ng.
8. Temp devia�on:
The devia�on is 1°C. The thermostat start to work when the actual temp is 1°C lower than set
temp and stop to work when the actual temp is 1°C higher than set temp.
9.Reverse output:
This func�on works for the cooling system. When the temp is 1°C higher than set temp, the
thermostat will disconnect the cooling system. otherwise, it will connect the cooling system.
10. Schedule:
Select a weekly schedule for the Edit. There are 2 op�ons:
7: each day from Mon to Sun can be set individually.
5+1+1: 5 days from Mon to Fri have the same events, Sat and Sun can be set individually.
11. Adap�ve func�on:
A�er several days of installa�on and use, Adap�ve func�on ensures that the required temp
has already been reached when the next event begins.
12. Reset:
All parameters are restored to default values.
7.9 Open window detec�on
This func�on only works when room sensor or both sensors is selected. The thermostat with this
func�on will shut off automa�cally for 15 min when the window opens, as it can detect that the
room temp plummets.
12