Section 363-765-105
8.6
Protector Plugs. For the FRE-765 List 5A, install five-pin protector plugs into the protector strips
for each subscriber line installed (Figure 6). See Table 7 for protector socket locations.
8.7
Auxiliary Power Pairs. When PG-Flex is used with a doubler, install the two AMP Quiet Front
terminations (PN 150-1399-25) and wire for the doubler. The installation kit provides white and blue
jumper wires. Install the two AMP Quiet Front terminations into the FRE-765 (Figure 7) enclosure:
1
Connect a white jumper wire to PWR_1_T (J10) and a blue jumper wire to PWR_1_R (J11)
barrel connectors.
2
Connect a white jumper wire to PWR_2_T (J12) and a blue jumper wire to PWR_2_R (J13)
barrel connectors.
3
Back out the phillips-head screw for each connector and slide the bracket on the AMP Quiet
Front terminator under it.
4
Tighten the phillips-head screw.
5
Insert and tighten the white and blue jumpers into the AMP Quiet Front terminations.
Page 14
June 2, 1997
Figure 6. Installing Five-Pin Protector Plugs
PairGain Engineering - Plant Series
Revision 01
PG-Flex FRE-765