Part 3

Electrical Connection

Dimensions
3/4"
C
D
115 Volt Single Phase Fans
Green/Yellow
Motor
Blue
Leads
Black
Brown
Capacitor
Wiring Diagram (for connecting "Remote" blowers to CopperSmith Pro & Standard Series liners*)
Black
120 volt AC from electrical panel (usually black) to liner
White
Neutral from electrical panel (white) to liner
Green
Ground from electrical panel (usually green) to liner
Red
120 volt AC variable control from liner to 120 volt AC of variable speed ventilator (usually black)
CAUTION: Do NOTconnect this wire to a 3-speed blower.
House Electrical
Liner Models:
CSPI Series
CSCI Series
Excluding...
3-speed motor
models, which all
have a
-6 or -12
at the end of
model number.
It is the owner's responsibility to ensure that a qualified person performs the electrical connection of this appliance. The electrical installa-
tion, including minimum supply wire size, must comply with the National Electric Code ANSI/NFPA 70-1990 (or latest revision) and local
codes and ordinances. A copy of this standard may be obtained from: National Fire Protection Assoc., 1 Batterymarch Park, Quincy, MA
02269
CopperSmith, Remote Blower Installation Instructions (All Models), Revised 09-18-16
A B
Control
(Ground)
Voltage
N (White)
From
Switch
L (Black)
In Hood
Panel
Green
White (N)
120V Black
(L)
BLK
Liner
Dimensions Data & Amperage
Model
A
WARNING:
Ensure the power supply is disconnected before
proceeding.
Verify that the power supply matches the ratings found
on the blower data label before proceeding.
The complete blower unit must be properly grounded at
all times when electrical power is applied.
Do not ground the appliance with the neutral (white)
house supply wire. A separate ground wire must be
utilized.
Failure to complete electrical connections properly may
result in damaged or non-functional systems. Follow
instructions carefully to ensure proper installation.
120V Red
WHT
GRN
RED
B
C
D
Amps
13
6
8
Ventilator
Green, Ground
1.26
2.99
4.84