Connection to GrowControl™ GCX
All GrowNET™ devices are connected using standard CAT5 Ethernet cable with RJ-45 connections.
Devices can be connected directly to the GrowNET™ ports on the bottom of the controller, or through HX8
GrowNET™ hubs. It is typical to simplify cabling by locating hubs centrally in hall ways and rooms allowing
single runs from an 8-port device hub back to a central hub or back to the controller.
Refer to the GCX controller manual for details on adding the device to the system.
Connection to MODBUS RTU
Use the LX2 ModLINK to connect RS-485 MODBUS devices to the GrowNET™ port.
See MODBUS manual for more information.
MODBUS Manual
GrowNET™ Hubs
HX8 GrowNET ™ hubs expand a single port into eight more ports.
Hubs can be daisy-chained to form a network of up to 100 devices per
GrowNET™ bus. Individually buffered port transcievers provide excellent
signal integrity and extended communication strength and range.
Hubs provide up to 1A of power for operating sensors and most relays
directly over the CAT5 cable. A DC jack on the hub provides 24Vdc power
to the ports from the included wall power supply. A terminal block
power option is also available.
4
© Agrowtek Inc. | www.agrowtek.com | Technology to Help You Grow™
RJ45/CAT5
7 - 24 Vdc
RS-485
3.3/5Vdc Serial Bus Compatible.
Include required bus terminating resistors per EIA standard.
PLC
TX/RX-
TX/RX+