Coralife Turbo-Twist 3x Посібник - Сторінка 4

Переглянути онлайн або завантажити pdf Посібник для Лабораторне обладнання Coralife Turbo-Twist 3x. Coralife Turbo-Twist 3x 5 сторінок. Uv sterilizer
Також для Coralife Turbo-Twist 3x: Інструкція з експлуатації (6 сторінок), Інструкція з експлуатації (12 сторінок)

Coralife Turbo-Twist 3x Посібник
TROUBLE SHOOTING
The plug is not connected
to the power supply
UV-C Lamp
UV lamp base is loose
is not working
The lamp has expired
The hose lock nut is
loose
Water leak
between the
main body and
hose lock nuts
The O-ring is not in
place
UV-C LAMP REPLACEMENT
The UV-C lamp has a useful life of about 8,000 hours.
To ensure effective performance, replace the UV-C lamp
before it expires.
How to replace the UV-C lamp
Disconnect the sterilizer from the power supply. (It is also necessary to disconnect the
power to the water pump).
Remove the threaded cap to
uncover the lamp socket.
SOCKET
Pull the UV-C lamp out of the socket
(Be careful not to touch the lamp as it
may be hot).
Make sure that the pins of the lamp plugs
into the socket indicated with a "click".
Reverse steps 5-1 to reassemble the Turbo-Twist.
Connect the plug to the
power supply
Push the UV-C lamp onto the
socket until a "click"is heard
Replace the UV-C lamp
Tighten the hose barb or the
hose lock nut
Install the O-ring
Unplug the UV-C lamp out of the main body.
UV LAMP
UV LAMP
SOCKET
WARNING
Please read the instructions in their entirety before
attempting to use this unit.
Cut off the power and stop using if
the unit was submersed or dampened
by water
Cut off the power if there is a burning
or smoking smell.
Never look directly at the unshielded
lamp as the ultraviolet radiation
emitted from the lamp can be harmful.
Always leave a drip-loop in the power
cord to prevent water from running
down the length of the
cord and reaching
the power
outlet.
The water temperature flowing
through the unit should be below
o
o
105
F (40
C).
Always disconnect the unit from the
power supply before shutting down
the flow of water to prevent the unit
from overheating.
Cut off the power immediately if water
enters into the Quartz Housing.
Never connect the sterilizer to the
power outlet while hands are wet.
Do not pull cord to disconnect power.
Though the Turbo-Twist is water
resistant, it should never be
intentionally submersed in water.
Always install the sterilizer in a location
where there is little likelihood of flooding
or water dripping directly onto the unit.
Make sure that appropriately sized
hose lock nuts are positioned on
hose barbs before attempting to
connect tubing.
Only a 120V (60 Hz) electrical
source should be used with the
Turbo-Twist.