Troubleshooting

• The plug is not connected to
the power supply.
UVC Lamp
• UVC lamp base is loose.
is not working
• The lamp has expired.
• The hose lock nut is loose.
Water leak
between the
main body and
hose lock nuts
• The O-ring is not in place.
UVC Lamp Replacement
UVC Lamp Replacement
The UVC lamp has a useful life of about 12 months. To ensure
effective performance, replace the UVC lamp once per year.
How to replace the UVC lamp
➀ Disconnect the sterilizer from the power supply. (It is also necessary
to disconnect the power to the water pump.)
➁ Remove the threaded cap to
uncover the lamp socket.
SOCKET
➃ Once cool, pull the UVC lamp out
of the socket (Be careful not to
touch the lamp as it may be hot).
➄ Make sure that the pins of the lamp plugs
into the socket indicated with a "click".
➅ Reassemble the Turbo-Twist.
7
PROBLEM
SOLUTION
• Connect the plug to the
power supply.
• Push the UVC lamp onto the
socket until a "click" is heard.
• Replace the UVC lamp.
• Tighten the hose barb or the
hose lock nut.
• Install the O-ring.
➂ Unplug the UVC lamp out of the main body
and allow to cool.
UVC LAMP
UVC LAMP
SOCKET
W A R N I N G
Please read instructions in their entirety
before using the UV Sterilizer.
Cut off the power and stop using
if the UV Sterilizer was submersed
or dampened by water.
Cut off the power if there is a
burning or smoking smell.
Never look directly at the
unshielded lamp as the ultraviolet
radiation emitted from the lamp
can be harmful.
Always leave a drip loop in the
power cord to prevent water from
running down the length
of the cord and
reaching the
power outlet.
The water temperature fl owing
through the UV Sterilizer should
be below 105
o
F (40
o
C).
Always disconnect the UV Sterilizer
from the power supply before
shutting down the fl ow of water
to prevent overheating.
Cut off the power immediately
if water enters into the quartz
housing.
Never connect the sterilizer to the
power outlet while hands are wet.
Do not pull cord to disconnect
power supply.
Though the Turbo-Twist is water
resistant, it should never be
intentionally submersed in water.
Always install the sterilizer in a
location where there is little likelihood
of fl ooding or water dripping onto the
UV Sterilizer.
Make sure that appropriately-sized
hose lock nuts are positioned on
hose barbs before attempting to
connect tubing.
Only a 120V (60 Hz) electrical
source should be used with the
Turbo-Twist.