Product Installation Guidelines
ADJUSTMENT OF THE MIX TEMPERATURE (SHOWER MIXERS)
1. Set the handle to cold position.
4. Remove the lower brass ring
(temperature setting ring) and
rotate the brass ring clockwise
to increase temperature or
anti-clockwise to decrease.
Refit to spline in new position.
© Galvin Engineering Pty Ltd
2.
Unscrew the tamper
proof screw from handle.
Pull out handle assembly
from the body
5. Reposition the upper
ring in the same
position against step.
Version 1, 11 January 2022, Page 4 of 5
3. Remove the upper brass ring.
ke sure the
ntr
rotate during the next steps.
6. Once set, reverse step 2 to
reassemble.
7. Re-test temperature to ensure
correct operation.