Galvin Specialised Ezy-Wash TF78WC-ESS Інструкція з монтажу виробу - Сторінка 3

Переглянути онлайн або завантажити pdf Інструкція з монтажу виробу для Сантехніка для кухні та ванної кімнати Galvin Specialised Ezy-Wash TF78WC-ESS. Galvin Specialised Ezy-Wash TF78WC-ESS 4 сторінки. Food service tapware

3. Fit grub screws
 Ensure the body is pushed firmly against the tail and
then secure in place with the supplied grub screws.
 Ensure all four (4) grub screws are fitted with the
supplied allen key. If grub screws are missing,
contact us on 1300 514 074.
5. Fit wall flange
 Extend the stainless steel cable upwards and place
the flange against the wall.
 Ensuring there is adequate tension in the cable, mark
out the 6 mm flange holes with 48mm center
distance.
 Before drilling, ensure the flange is level and is central
to the tap body.
 Drill the holes, fit wall plugs, and secure the wall flange
using the supplied screws.
Note: Supplied fasteners may not be suitable for the
mounting surface. If this is the case, suitable fasteners will
need to be sourced by the installer
7. Test unit.
Once all parts are secure, open the lever handles and ensure there is flow
from both hot and cold inlets. Inspect the tap and check for any leaks.
4. Fit bracket
 With the supplied screws, secure the top and
lower halves of the bracket to the spout
 As a reference the bracket should be first
installed 165mm from the wall as shown.
 Ensure hook is facing forward and only tighten
the bracket lightly.
6. Adjust the bracket
 Adjust bracket if the cable is too loose or too
tight.
 Completely tighten screws to secure bracket.
Take care not to overtighten.