Galvin Specialised Ezy-Wash TF85-C Посібник з встановлення виробу - Сторінка 4

Переглянути онлайн або завантажити pdf Посібник з встановлення виробу для Сантехніка для кухні та ванної кімнати Galvin Specialised Ezy-Wash TF85-C. Galvin Specialised Ezy-Wash TF85-C 5 сторінок. Pre-rinse tapware

5. Secure support rod
1. Fasten support rod securely against CP
riser.
2. Tighten compression nut on wall bracket
to secure the support rod. The rod is now
rigid.
WARNINGS
For optimum performance it is recommended that the isolation or mains taps are turned off whilst the unit is
not in use (overnight etc.), so that the unit is not under mains pressure when unsupervised. Flood damage
may occur if a failure occurs whilst the unit is under mains pressure (warranty is void in this instance).
Galvin Specialised recommends that the handpiece is periodically serviced by a qualified plumber .
IMPORTANT:
To seal the hose this unit uses Loctite 577 which is a thread sealant approved for use with potable water
(AS/NZS 4020). If hose is to be removed for maintainance purposes, reseal the joints with Loctite 577, or
an equivalent sealant compliant with AS/NZS 4020. Do not use thread tape to seal the hose connections,
as this may cause the hose nut to become loosened over time and leak.
Version 2, 4 August 2017, Page 4 of 5
6. Test unit
 Once all fittings have been tightened
securely, connect the unit to the mains
water.
 Turn on water and test the unit for any
leaks.