WWW.GAMAINC.COM
Each transmitter has its own unique internal address along with the data as to which button is pressed and transmitted.
The receiver needs to be programmed to respond only to the specific transmitter it is intended to operate with. The
following steps configure the receiver to operate with a particular transmitter. Up to 30 transmitters can be programmed
to one receiver. Please read the entire programming procedure before starting. Make sure the receiver is connected to
power before programming. When the receiver enters program mode, all previous transmitter addresses that were
programmed will be erased from the receiver's memory.
1. Locate the pushbutton labeled "PROGRAM" on the receiver. Press and hold this button until the red LED next to the
program button illuminates (approximately 3 seconds). The receiver is now in the transmitter program mode. Release
the button. At this point all previously programmed transmitter addresses are erased from the receiver's memory.
2. Press and release any button on the transmitter and verify that the red program LED extinguishes and then
illuminates (blinks once).
3. Repeat previous step for additional transmitters that will operate with this particular receiver. The red LED on the
receiver will extinguish and illuminate (blink) each time a transmitter is programmed.
6. The receiver will return to normal mode if no transmitter buttons are pressed for 5-seconds. The red LED on the
receiver will blink rapidly, then extinguish. The receiver is now in the normal mode of operation. This completes the
programming instructions. The receiver will retain all of its programming even when power is removed.
Long Range
Antenna Jack
Dip Switch
Programming
Programming Instructions
Independent Contact
Switch
Terminals
Closure
Programming
LED
LEARN
GAMA ELECTRONICS, INC.
WWW.GAMAINC.COM
RFR24VPRWP
MOTOR
GND +24V
Power
Motor
Terminals
RFR24VPRWP
Instruction Manual
Page 2 REV A 06/17/20