4 INSTALLATION AND ASSEMBLY

4.1 For a satisfactory installation of the product is important to:
• Verify that the gate complies with the legal requirements and then define the complete project of the installation;
• Verify that the gate is well balanced and that it has no points of friction in opening and closing;
• Identify an area that allows a smooth and safe manual operation of the operator;
• Verify that the operator bulk is compatible with the area chosen for the fitting (Pic. 2);
• Ensure that the space for the rotation of the arm is sufficient (Pic. 3).
• Use the length/weight graphic and the provided installations dimensions (Pic. 4) evaluating whether you prefer a 90° or a 120°
opening.
4.2 Once you have defined and satisfied these requirements, proceed with the assembly:
• fix the operator fixing plate to the pillar by using screws and plugs suitable to the type of surface and material (Pic. 5);
• mount the straight arm by using the supplied screw and washer (Pic. 6);
• insert the operator inside the wall connection plate and fix it with the provided screws and nuts (Pic. 7);
• Mount the swing fixing hinge and the curved arm to the straight arm by using the provided pins and seeger rings (Pic. 8);
• weld the hinge to the gate or fix it with screws suitable to the type of material;
4.3 How to unlock the operator
WARNING Disconnect the power supply from the control panel before releasing the operator. In case you cannot turn the power off, you
will necessarily have to re-lock the motor in the position in which it was unlocked.
Lift the cover window (Pic. 9a) and, after having inserted the unlocking key, rotate clockwise until it stops (Fig. 9b).
4.4 How to fix and adjust the mechanical limit switches
• Unlock the operator;
• Rotate the wing to the position of complete opening, position the mechanical limit switch on the stop with the straight arm and fasten it
with the provided screws (Pic. 10). If necessary, you can mount a second mechanical limit switch for the closing stop. In this case follow
the above directions by moving the door in the desired closed position and fix it with the screws provided in detention;
• Repeat the previous step for a possible second door;
• Secure the protective cover on the straight arm with the screws provided (Pic. 10).

5 ELECTRICAL CONNECTIONS

Run the motor connections following the wiring diagrams.
WARNING For adequate electrical safety, keep low safety voltage wires (controls, electro-locks, antenna, auxiliary power) clearly separate
from 230V ~ power wires (minimum 4 mm in air or 1 mm via supplementary insulation) placing them in plastic raceways and securing
them with adequate clamps near terminal boards.
WARNING For connection to the mains, use a multipolar cable having a minimum section 3x1,5 mm² and complying with the current
regulations. For connecting the motors, use a minimum cross section 1,5 mm² cable and complying with the current regulations. As
an example, if the cable is out side (outdoor), must be at least equal to H05RN-F, whereas if it (in a raceway), must be at least equal to
H05VV-F.
WARNING All wires must be striped and unsheathed in the immediate vicinity of terminals. Keep wires slightly longer to subsequently
eliminate any excess.
WARNING Maintain the ground conductor at a major length respect the active conductors so that, if the cable exit from its fixing housing,
the active conductors tighten up as first.
Program the control board to complete all adjustments. It is now possible to supply a complete installation in compliance with all stan-
dards required for gate automation. See the instructions provided with the control panel to be connected.
Finally, verify that all adjustments operations have been correctly performed and that safety devices and unlocking device properly
work.