Dean Hembury 8 Інструкція з експлуатації Посібник з експлуатації - Сторінка 8
Переглянути онлайн або завантажити pdf Інструкція з експлуатації Посібник з експлуатації для Піч Dean Hembury 8. Dean Hembury 8 17 сторінок.
Chimney
All Dean Stoves must have a minimum chimney height of 4m measuring from the stove outlet,
the chimney must not be less than 150mm (6") internal diameter.
These stoves are not suitable to be used in a flue-shared situation.
The chimney must be sound and of not too large in section. If not sound or too large, a liner
will have to be fitted; Stainless steel or ceramic liner suitable for solid fuel.
If the chimney draw is too high a flue stabilizer will have to be installed. When the chimney is
warm the draw should not be lower than 0.10 water gauge.
All appliances have been tested at 12 PA with the doors closed.
When a flue is connected directly into an existing chimney without a liner the register plate
must be fitted with removable doors to facilitate cleaning. If it not possible to fit doors in the
register plate then a cleaning door will need to be fitted as near as possible to the connecting
length of flue in the front, side or back of the chimney breast.
Hearth, Surround and Register Plate
The stove must stand on non-flammable material at least 12mm thick (1/2"). The hearth must
extend 300mm in front of the firebox and 150mm to the sides.
If the stove is installed into a fire opening made of non-combustible materials, we recommend
a minimum of 150mm gap to the sides and 300mm above from non-combustible materials.
The appliance must be installed on a floor with an adequate low bearing capacity.
If the construction doesn't meet the existing prerequisite the floor must be reinforced or a load
distributing plate could be fitted.
Table of distances from combustibles
Stove Type
Hembury 8 SE
It may be necessary to shield a beam or mantle piece from the heat. The single wall flue must
be at least 3 times its diameter away from combustible materials i.e. 150mm (6") flue 450mm
(18") away from combustible materials.
Be careful not to place furniture or other combustible material too close to the stove.
Minimum from back of
appliance to combustibles
850mm
8
Minimum from side of
appliance to combustibles
700mm