Gree LE60-13/C1 Посібник користувача - Сторінка 15

Переглянути онлайн або завантажити pdf Посібник користувача для Контролер Gree LE60-13/C1. Gree LE60-13/C1 18 сторінок. Rf remote controller
Також для Gree LE60-13/C1: Посібник користувача (18 сторінок)

Gree LE60-13/C1 Посібник користувача
RF Remote Controller LE60-13/C1

4 Operation Instructions

4.1 Matching Setting

When using RF remote controller for the first time, please conduct the matching
with the zone control system. Matching method: turn on match mode of wired remote
controller and press "ON" and "OFF" buttons at the same time for 5s; when green
indicator and red indicator are on and off alternatively, it indicates RF remote
controller has entered into the match mode.
When entering into match mode, if matching is not succeeded within 5min, the
red indicator will flash quickly for 10s and then exit from the match mode. If matching
is succeeded, the green indicator will flash quickly for 10s and then exit from the
match mode.

4.2 Air Valve Setting

RF remote controller can open or close the air valve at current ares. Press "ON"
button and then the green indicator will flash once and the air valve at current area
will open; press "OFF" button and then the red indicator will flash once and the air
valve at current area will close;
NOTE!
When operating the RF remote controller, make sure it is within the receiving
range of the Zone Control Interface;
9