Parameter
General specifications
State indication Low Battery
Normal operation
Alarm
Sound pressure of alarm
LED
Fire alarm
increased sampling rate
Normal mode
Pushbutton
During normal operation
In case of an alarm
Approval
5. Mounting
Mount the product to the ceiling, if possible in the middle of the room.
5.1 Preparing mounting
• If you intend to mount multiple products, start by creating a mounting plan
with the appropriate mounting locations. Then label the products with
numbers or the corresponding mounting location to help avoid confusion of
mounting locations.
• Prior to mounting, verify that the solar-operated energy storage module of
the OPUS wireless heat detector has been charged.
– Regular daylight is sufficient for charging the energy storage module.
– Exposure to direct sunlight reduces the charging time.
• Verify that the solar cell of the OPUS wireless heat detector is mounted
facing towards the light source.
5.2 Teaching in
• Verify that the OPUS wireless heat detector is in the vicinity of the
OPUS SmartHome Gateway.
• Verify that the OPUS SmartHome Gateway is in "Learn" mode. See the ope-
rating instrucions of the OPUS SmartHome Gateway for detailed information.
NOTE
ELECTROSTATIC DISCHARGE
• Always earth yourself before touching electronic components, for example,
the LRN key.
Failure to follow these instructions can result in equipment damage.
Wert
A short acoustic signal sounds
and the red LED flashes every
48 seconds.
– When this acoustic signal
starts, the heat detector AHD
can be operated for another
30 days or 4 minutes in the
case of an alarm.
The red LED flashes every
48 seconds.
Sound sequence.
The red LED flashes every
0.5 seconds.
85 dB
flashes every 0.5 seconds
flashes every 2 seconds
flashes every 48 seconds
Function test: Signal sounds
and red LED flashes
Pressing the pushbutton
mutes the alarm sound for
10 minutes.
EN 54-5, class A1/R for heat
detection systems.
Audible signal pattern in
the case of an alarm as per
ISO 8201 EN 61000-6-
3:2007+A1:2011
EN 50130-4:2011+A1:2014
RoHS, Reach
1. Press the LRN pushbutton (A) of the wireless mounting base ASD 10
with an object that is not pointed and not conductive.
- The wireless mounting base ASD 10 sends a Learn telegram (LRNTEL)
to the OPUS SmartHome Gateway
- The wireless mounting base ASD 10 is now connected to the OPUS
SmartHome Gateway.
5.3 Mounting the wireless mounting base ASD 10
• Verify that the mounting position of the wireless mounting base ASD 10
conforms to the mounting plan.
• Verify that a lithium battery (option) is used if the wireless mounting base
ASD 10 is used in darker environments.
1. Choose an installation site without direct exposure to sunlight.
– Direct sunlight causes incorrect temperature values.
2. Turn (bayonet joint) the cover/holder from the housing (wireless mounting
base ASD 10).
3. Mount the cover/holder with the enclosed mounting material
(screws and dowels).
4. Turn (bayonet joint) the wireless mounting base ASD 10 (A) onto
the cover/holder.
5.4 Screwing the heat detector AHD
1. Remove the label (A) with the CE
mark from the heat detector AHD.
– The operation of the product may
be influenced if you do not remove
the label.
2. Keep the label, for example,
by sticking it into the operating
instructions.