storage container, the ice full indicator on the display panel
will light on and the ice maker will stop automatically;
If there is a water shortage or something wrong with the water
supply system, the water shortage indicator will light on and the
ice maker will stop operation automatically.
6. For the ice
f laker
use purified water as water source, if the water
shortage indicator light and no ice is made when start the ice
f laker
procedure, maybe there is air in the water inlet tube. Unplug
one end connecting water inlet tube and water valve of ice
then open water inlet switch till there is water and air come from
another end. Then connect the water inlet tube with water valve of
ice
f laker
quickly.
MAINTENANCE:
1.If the compressor stops for any reasons like water shortage, too
much ice, power off, etc., Don't restart it right away. You can
restart it 5 minutes later to protect compressor.
2.Check regularly the connectors of the water inlet and outlet tubes
and drain the little surplus water that may occur.
3.If the ice
f laker
will be unused for long periods of time, please
screw off the plastic drainage connector screw on the back of the
ice
f laker
so as to drain the surplus water in the water groove. Then
screw it on. Wipe the inner liner of the ice storage container with a
clean rag.
4.When plugging or unplugging,
the plug should be held by hand
and the wires should not be
dragged heavily.
5.Please clean the ice
f laker
and its water supply system for one time
every month. The ice
f laker
should be unplugged before cleaning.
6
f laker
,
3.The ice
flaker
should be placed on
horizontal and structurally sound
ground and away from heat source
and corrosive gas.
At least about 150mm room
should be left around the ice
maker to ensure the fine ventilation.
4. Please adjust the feet when placing the ice maker some where,
otherwise the water level will be effected and so do the ice
shape.Before using the ice
f laker
wait about 12 hours after positioning it in a proper place.
5. The outlet of drainage tube should be lower than cabinet so as to
drain water easily.
6. Voltage range:
187V
187 ~ 242 V
7. The rated capacity of wire should be over 6A, the section area of
2
the wire is 0.75mm . The wire could be consisted by single ply or
multiplies. The rated current of fuse is 5A.
8.The grounding must be good.
>150mm
>150mm
>150mm
for the first time, you should
220V
242V
3