Gree MULTI30HP230V1EO Посібник з встановлення та експлуатації - Сторінка 10

Переглянути онлайн або завантажити pdf Посібник з встановлення та експлуатації для Кондиціонери Gree MULTI30HP230V1EO. Gree MULTI30HP230V1EO 16 сторінок. Split type wall-mounted air conditioner

Gree MULTI30HP230V1EO Посібник з встановлення та експлуатації
ELECTRICAL CONNECTIONS
1.
Remove the handle at the right side plate of the
outdoor unit (one screw).
2.
Remove the cable clamp, connect the power
connection cable with the terminal at the row of
connection and fix the connection. The fitting line
distributing must be consistent with the indoor
unit. terminal of line bank. Wiring should meet
that of indoor unit.
3. Fix power connection wire by wire clamp.
4.
Ensure wire has been fixed well.
5.
Install the handle.
Including an air switch with suitable capacity,
please note the following table. Air switch
should be included magnet buckle and heating
buckle function, it can protect the circuit-short
and overload. (Caution: please do not use the
fuse only for protect the circuit)
Air-conditioner
MULTI24HP230V1EO
Air switch capacity
25A
To unit A
L1 L2
Power cord
connecting
cable
A
L1
L2
N(1) 2
3
black
white
green
white
red
black
(brown)
(blue)
(yellow-green)
(blue)
(brown)
L1 L2
INDOOR UNIT A
POWER
An all-pole disconnection switch having a contact
separation of at least 3mm in all pole should be
connected in fixed wiring.
Wrong wire connection may cause malfunction of
some electric components.After fixing cable, ensure
that leads between connection to fixed point have
some space.
The connection pipes and the connection wirings
of the unit A, unit B and unit C must be corresponding
to each other respective.
The appliance shall be installed in accordance with
national wiring regulations.
Note: The above figures are only intended to be a simple
diagram of the appliance and may not correspond to the
appearance of the units that have been purchased.
To unit B
connecting
cable
B
2
3
N(1)
green
white
red
green
white
black
(yellow-green)
(blue)
(brown)
(yellow-green)
(blue)
INDOOR UNIT B
8
INSTALLER
To unit C
connecting
cable
To the power supply
C
2
3
N(1)
red
green
black
(brown)
(yellow-green)
INDOOR UNIT C