6 APPENDIX A: SAMPLE CSI PROGRAM

6
Appendix A: Sample CSI Program
;{CR23X}
;
;Program to read Decagon's Dielectric Leaf Wetness ;Sensor (LWS)
;
;Wiring: white to EX1, red to 1H, shield to gnd
;
;This program separates LWS output into three bins
;bin 1 = output < 330mV - dry sensor
;bin 2 = 330mV < output < 337mV - wet sensor even when contaminated
;bin 3 = output > 337 mV - wet sensor
;The values output to final storage by the histogram
;command are the fraction of the OUTPUT INTERVAL that
;had sensor output in the preceding ranges
;
;Note that the wetness thresholds depend on excitation
applied. If you are exciting with other than ;3000 mV,
you will need to determine a custom wetness ;threshold
*Table 1 Program
01: 1
1: Excite-Delay (SE) (P4)
1: 1 Reps
2: 20 Auto, 60 Hz Reject, Slow Range (OS>1.06)
3: 1 SE Channel
4: 1 Excite all reps w/Exchan 1
5: 1 Delay (0.01 sec units)
6: 3000 mV Excitation
7: 1 Loc [ LWS_mV
8: 1.0 Multiplier
9: 0.0 Offset
2: If time is (P92)
1: 0 Minutes (Seconds --) into a
2: 60 Intervl (same units as above)
3: 10 Set Output Flag High (Flag 0)
3: Real Time (P77)^14490'
1: 1110 Year,Day,Hour/Minute (midnight = 0000)
4: Sample (P70)^21634
1: 1 Reps
2: 1 Loc [ LWS_mVn
Execution Interval (seconds)
]
]
even when contaminated
14
LWS