Bristan Z2 SQR 1/2 C Інструкція з монтажу та посібник користувача
Maintenance - Valve Cleaning
2
1
Important
Prior to doing any
maintenance or
servicing the isolation
valves must be turned
to the
closed/off position.
Remove handle
5
4
Clean the seal
around the
valve and apply
silicon grease
Check that the groove
Remove
valve from
the casing
Maintenance- Flow Straightener
2
1
Unscrew
the flow
straightener
3
Pull out valve
body from tap
6
Assemble
the valve.
apply
grease and
place back
into the tap
body.
is clear of any debris
on the inside of valve
casing.
3
Rinse
the flow
straightener
Replace
the flow
straightener
into spout
General Cleaning
Using a flat screw
driver, remove the
Your fitting has a high quality finish and should be treated with care to preserve the visible
spring and spline.
surfaces.
All surfaces will wear if not cleaned correctly, the only safe way to clean your mixer tap is to wipe
with a soft damp cloth. Stains can be removed using washing up liquid. All bath cleaning powders
Rinse and leave to
and liquids will damage the surface of your fitting, even the non-scratch cleaners.
one side.
Note: Never use abrasive detergents or disinfectants or those containing alcohol, hydrochloric acid
or phosphoric acid.
Troubleshooting
Symptom
Cause
Partially closed isolation valve.
Instantaneous water heater cycles on
and off as flow rate or pressure is too
low.
Replace
Head of water is below the
handle
No flow or
minimum distance required.
low flow
Hot or cold water being drawn off
rate
elsewhere causing pressure changes
or instantaneous boiler temperature
changes.
Airlock or partial blockage in the supply
pipework.
This is normal for a short time after using
Water
the taps.
dripping
If water continues to drip,
from taps
possibly due to the ceramic disc valves
Closed isolation valve.
Taps do not
turn on
Mains water supply turned off.
Notes
Please use this space for any notes you or your installer may have regarding the installation/
At Bristan, we want to make things as easy as possible for our customers. That's why we offer solid guarantees on
all our products, effective from the date of purchase, to give you peace of mind.
To start your free guarantee simply scan the QR code and register your product. Alternatively visit
www.bristan.com/register to register your product via a computer.
For full guarantee terms and conditions visit www.bristan.com/guarantees.
Remedy
Open isolation valve.
Increase water flow rate or
pressure through system.
5 meters minimum required.
Do not use other water outlets when using the taps.
Flush through pipework to ensure removal of debris
and any airlocks.
This is caused by residual water tension, the build up
of water in the tap body.
Remove valves and clean, refer to 'Maintenance'
section before starting any maintenance.
Open isolation valve.
Turn on mains water supply.
plumbing of this product.